Increased intimal hyperplasia in experimental vein graft stenting compared to arterial stenting: comparisons in a new rabbit model of stent injury.
نویسندگان
چکیده
BACKGROUND In-stent restenosis due to intimal hyperplasia is an important clinical problem. Animal models of stent injury are limited by inconsistent arterial responses to stenting, and less intimal hyperplasia than diseased human vessels. To address these issues, we aimed to compare the degree of intimal hyperplasia in stented rabbit jugular-carotid interposition grafts (vein grafts) versus stented carotid arteries. METHODS Jugular-carotid vein grafts were constructed in rabbits, then stented or left unstented. Carotid arteries were treated with similar stents or left instrumented only. After 3 or 28 days, vessels were perfusion fixed, embedded in resin, and sections were cut with a diamond saw. Intimal and medial thicknesses were measured in stained sections. RESULTS After 3 days, inflammatory changes were observed in the intima of all stented vessels. After 28 days, intimal thickness in stented vein grafts was 2-fold greater than in control vein grafts and approximately 4-fold greater than in stented carotid arteries. In addition, the intimal hyperplasia response was markedly more consistent in stented vein grafts compared with stented carotid arteries. CONCLUSIONS Stent deployment in experimental vein grafts results in increased and more reproducible smooth muscle cell intimal hyperplasia than carotid arterial stenting. This is a promising small-animal model for investigating the intimal response to stenting.
منابع مشابه
Arterial repair after stenting and the effects of GM6001, a matrix metalloproteinase inhibitor.
OBJECTIVES This study compared the extracellular matrix (ECM) and cellular responses after stenting to balloon angioplasty (BA) and to determine the late effects of matrix metalloproteinase (MMP) inhibition on arterial repair after stenting. BACKGROUND Although stenting is the predominant form of coronary intervention, there is limited understanding of the early and late arterial response. ...
متن کاملInhibition of accelerated atherosclerosis in vein grafts by placement of external stent in apoE*3-Leiden transgenic mice.
OBJECTIVE Vein grafts fail because of the development of intimal hyperplasia and accelerated atherosclerosis. Placement of an external stent around vein grafts resulted in an inhibition of intimal hyperplasia in several animal studies. Here, we assess the effects of external stenting on accelerated atherosclerosis in early vein grafts in carotid arteries in hypercholesterolemic apolipoprotein E...
متن کاملLong-term outcomes of saphenous vein graft stenting compared with native coronary artery stenting in patients with previous coronary artery bypass graft surgery.
OBJECTIVE Our main objective was to compare the in-hospital and long-term outcomes of saphenous vein graft stenting and native coronary artery stenting in patients with previous coronary artery bypass grafting. METHODS We studied 127 patients who had prior coronary artery bypass; they were divided in two groups, according to the kind of percutaneous coronary intervention performed. The first ...
متن کاملStudy of the patency of small arterial branches after stent placement with an experimental in vivo model.
BACKGROUND AND PURPOSE The patency of intracranial perforating arteries after stent placement is unknown despite the general clinical use of intracranial arterial stenting. METHODS We deployed stainless steel stents in the abdominal aorta across the lumbar artery in eight normal rabbits in which the diameters of the abdominal arterial vessels were similar to those of human intracranial arteri...
متن کاملSonodynamic therapy decreased neointimal hyperplasia after stenting in the rabbit iliac artery.
BACKGROUND In-stent restenosis remains a pivotal problem after coronary and peripheral stenting. Sonodynamic therapy inhibits tumor growth by means of cytotoxicity after the activation of sonochemical sensitizers by ultrasound. PAD-S31 is known to be a water-soluble, chlorin-derivative sonochemical sensitizer. We assessed the efficacy of sonodynamic therapy using this sensitizer on neointimal h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular research
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2002