Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur.
نویسندگان
چکیده
PURPOSE In a meta-analysis of the literature we evaluated the present knowledge of the material properties of cortical and cancellous bone to answer the question whether the available data are sufficient to realize anisotropic finite element (FE)-models of the proximal femur. MATERIAL AND METHOD All studies that met the following criteria were analyzed: Young's modulus, tensile, compressive and torsional strengths, Poisson's ratio, the shear modulus and the viscoelastic properties had to be determined experimentally. The experiments had to be carried out in a moist environment and at room temperature with freshly removed and untreated human cadaverous femurs. All material properties had to be determined in defined load directions (axial, transverse) and should have been correlated to apparent density (g/cm(3)), reflecting the individually variable and age-dependent changes of bone material properties. RESULTS Differences in Young's modulus of cortical [cancellous] bone at a rate of between 33% (58%) (at low apparent density) and 62% (80%) (at high apparent density), are higher in the axial than in the transverse load direction. Similar results have been seen for the compressive strength of femoral bone. For the tensile and torsional strengths, Poisson's ratio and the shear modulus, only ultimate values have been found without a correlation to apparent density. For the viscoelastic behaviour of bone only data of cortical bone and in axial load direction have been described up to now. CONCLUSIONS Anisotropic FE-models of the femur could be realized for most part with the summarized material properties of bone if characterized by apparent density and load directions. Because several mechanical properties have not been correlated to these main criteria, further experimental investigations will be necessary in future.
منابع مشابه
Multi-level patient-specific modelling of the proximal femur. A promising tool to quantify the effect of osteoporosis treatment
Preventing femoral fractures is an important goal in osteoporosis research. In order to evaluate a person’s fracture risk and to quantify response to treatment, bone competence is best assessed by bone strength. Finite-element (FE) modelling based on medical imaging is considered a very promising technique for the assessment of in vivo femoral bone strength. Over the past decades, a number of d...
متن کاملMulti-level patient-specific modelling of the proximal femur. A promising tool to quantify the effect of osteoporosis treatment.
Preventing femoral fractures is an important goal in osteoporosis research. In order to evaluate a person's fracture risk and to quantify response to treatment, bone competence is best assessed by bone strength. Finite-element (FE) modelling based on medical imaging is considered a very promising technique for the assessment of in vivo femoral bone strength. Over the past decades, a number of d...
متن کاملDetermination of Relationships between the Ultrasound Velocity and the Physical Properties of Bovine Cortical Bone Femur
Accurate measurements of physical characteristics of bone are essential for diagnosis, assessment of change following treatment, and therefore, indirectly, for evaluation of new forms of therapy. This is particularly true of osteoporosis and aging skeleton, in which fractures occur easily. Methods: In this study an ultrasonic system was set-up and calibrated on Plexiglas tubes of variable thick...
متن کاملConstitutive modeling of cortical bone considering anisotropic inelasticity and damage evolution
Researchers have conducted finite element (FE) analyses with human models to predict injuries due to traffic accidents or falling. In most of their analyses, cortical bone was simply modeled as a general isotropic elastoplastic material. In this study, a constitutive model of cortical bone considering anisotropic inelasticity and damage evolution was developed to predict injuries more accuratel...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 33 10 شماره
صفحات -
تاریخ انتشار 2000