Heat-and-moisture exchangers used with biweekly circuit tubing changes: effect on costs and pneumonia rates.

نویسندگان

  • C Salemi
  • S Padilla
  • T Canola
  • D Reynolds
چکیده

In 1991, heat-and-moisture exchangers were introduced with biweekly ventilator circuit tubing changes, resulting in elimination of multiple pieces of respiratory equipment and reduced labor costs. The annual savings were $157,000, totalling $1.5 million since the onset of the program. There have been no increases in rates of ventilator-associated pneumonia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients.

OBJECTIVE To compare the degree of bacterial circuit colonization, frequency of ventilator-associated pneumonia (VAP), character of respiratory secretions, rewarming of hypothermic patients, disposable costs, and air flow resistance in intensive care patients ventilated using either a heat and moisture exchanger (HME) or hot water (HW) humidifier circuit. DESIGN A prospective, randomized blin...

متن کامل

Effectiveness of a heat and moisture exchanger in preventing hyperpnoea induced bronchoconstriction in subjects with asthma.

The effect of a heat and moisture exchanger, a device with hygroscopic material for conditioning inspired air, on hyperpnoea induced bronchoconstriction was studied in nine non-smoking volunteers with asthma, aged 19-32 years. Each had previously shown an increase of at least 100% in specific airways resistance (sRaw) to isocapnic hyperpnoea with dry air. On two separate days the subject perfor...

متن کامل

Experimental study of nanofluid effects on heat transfer in closed cycle system in shell and tube heat exchangers at Isfahan power plant

The present study investigated the effect of distilled-water/ silver nanofluid on heat transfer in a closed cooling system of one of the electrical energy generation units at Isfahan power plant. The difference between this study and previous researches refers to silver properties which have a high thermal conductivity and is non-toxic, hydrophilic and eco-friendly. Distilled water/ silver ...

متن کامل

Evaluating Humidity Recovery Efficiency of Currently Available Heat and Moisture Exchangers: A Respiratory System Model Study

OBJECTIVES To evaluate and compare the efficiency of humidification in available heat and moisture exchanger models under conditions of varying tidal volume, respiratory rate, and flow rate. INTRODUCTION Inspired gases are routinely preconditioned by heat and moisture exchangers to provide a heat and water content similar to that provided normally by the nose and upper airways. The absolute h...

متن کامل

Hydraulic Network Modeling to Analyze Stream Flow Effectiveness on Heat Transfer Performance of Shell and Tube Heat Exchangers

In this article, stream flow effectivness is based on hydraulic network studied in the shell-side of a shell and tube heat exchange as a case study. For an appropriate heat exchangers rating design to meet a specified duty, it's better to consider each stream flow separately. Using the hydraulic network principals, a set of the correlations for calculating different stream flow rates in the cro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2000