Interpreting ambiguous ‘trace’ results in Schistosoma mansoni CCA Tests: Estimating sensitivity and specificity of ambiguous results with no gold standard

نویسندگان

  • Michelle N Clements
  • Christl A Donnelly
  • Alan Fenwick
  • Narcis B Kabatereine
  • Sarah C L Knowles
  • Aboulaye Meité
  • Eliézer K N'Goran
  • Yolisa Nalule
  • Sarah Nogaro
  • Anna E Phillips
  • Edridah Muheki Tukahebwa
  • Fiona M Fleming
چکیده

BACKGROUND The development of new diagnostics is an important tool in the fight against disease. Latent Class Analysis (LCA) is used to estimate the sensitivity and specificity of tests in the absence of a gold standard. The main field diagnostic for Schistosoma mansoni infection, Kato-Katz (KK), is not very sensitive at low infection intensities. A point-of-care circulating cathodic antigen (CCA) test has been shown to be more sensitive than KK. However, CCA can return an ambiguous 'trace' result between 'positive' and 'negative', and much debate has focused on interpretation of traces results. METHODOLOGY/PRINCIPLE FINDINGS We show how LCA can be extended to include ambiguous trace results and analyse S. mansoni studies from both Côte d'Ivoire (CdI) and Uganda. We compare the diagnostic performance of KK and CCA and the observed results by each test to the estimated infection prevalence in the population. Prevalence by KK was higher in CdI (13.4%) than in Uganda (6.1%), but prevalence by CCA was similar between countries, both when trace was assumed to be negative (CCAtn: 11.7% in CdI and 9.7% in Uganda) and positive (CCAtp: 20.1% in CdI and 22.5% in Uganda). The estimated sensitivity of CCA was more consistent between countries than the estimated sensitivity of KK, and estimated infection prevalence did not significantly differ between CdI (20.5%) and Uganda (19.1%). The prevalence by CCA with trace as positive did not differ significantly from estimates of infection prevalence in either country, whereas both KK and CCA with trace as negative significantly underestimated infection prevalence in both countries. CONCLUSIONS Incorporation of ambiguous results into an LCA enables the effect of different treatment thresholds to be directly assessed and is applicable in many fields. Our results showed that CCA with trace as positive most accurately estimated infection prevalence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire

BACKGROUND Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A ...

متن کامل

Antioxidant effects of gold nanoparticles on Schistosoma mansoni induced granuloma, in vitro

Objective(s): Schistosomiasis and hepatitis C virus [HCV] co-infection is common among the Egyptian population. Co-infected patients have higher rate of chronic hepatitis, cirrhosis and hepatocellular carcinoma. The aim of the present study was to investigate the potential role of gold nanoparticles on granuloma in vitro. Materials and Methods: In the current study, granulocytes were isolated f...

متن کامل

Accuracy of circulating cathodic antigen tests for rapid mapping of Schistosoma mansoni and S. haematobium infections in Southern Sudan.

OBJECTIVE To evaluate the diagnostic accuracy of a circulating cathodic antigen (CCA) urine dipstick test for detecting Schistosoma mansoni and S. haematobium alongside an integrated rapid mapping survey in Southern Sudan. METHODS AND RESULTS A total of 373 children aged 5-16 years were included in the study. Of these 26.0% were infected with S. haematobium and 24.5% were infected with S. man...

متن کامل

Notes on the use of urine-CCA dipsticks for detection of intestinal schistosomiasis in preschool children.

Urine-dipstick diagnostic tests that detect schistosome circulating cathodic antigen (CCA) have the potential to provide more sensitive and rapid testing for intestinal schistosomiasis in field-based surveys; this is especially so when examining preschool children, from whom it may be difficult to obtain consecutive stool samples. To assess the performance of urine dipsticks, 569 preschool chil...

متن کامل

Improvement of POC-CCA Interpretation by Using Lyophilization of Urine from Patients with Schistosoma mansoni Low Worm Burden: Towards an Elimination of Doubts about the Concept of Trace

BACKGROUND Accurate diagnostic techniques for schistosomiasis are essential for prevalence determination and identification of positive patients. A point-of-care test for detecting schistosome circulating cathodic antigen (POC-CCA) has been evaluated for its accuracy in different endemic regions. This reagent strip/dipstick based assay has showed high sensitivity for individuals with high or mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017