Technetium-99m DTPA aerosol contamination in lung ventilation studies.

نویسندگان

  • D A Williams
  • C Carlson
  • K McEnerney
  • E Hope
  • C K Hoh
چکیده

UNLABELLED Contamination of working areas by 99mTc DTPA aerosol is of concern to nuclear medicine technologists. This study sought to determine the extent of 99mTc DTPA contamination to technologists, and to localize sources of aerosol leakage so that methods could be identified that would minimize contamination. METHODS Fifty to eighty millicuries 99mTc DTPA, diluted to a volume of 4-5 ml with normal saline, were injected into the nebulizing chamber of two commercially available inhalation aerosol systems. The patient's nostrils were clamped and a damp washcloth was wrapped around the patient's mouth. An alcohol swab was placed in the exit port of the exhaust filter in each delivery system, and the technologist involved wore a face mask during the inhalation phase. The patient breathed DTPA-labeled aerosol by mouth until the counting rate in the lungs was four times greater than the counting rate from the pulmonary perfusion phase. Connecting joints of the delivery system were then wipe tested. Last, a Geiger-Mueller detector (pancake probe) was used to survey all device components. Readings above 0.05 mR/hr were considered contaminated. RESULTS The patient was the greatest source of leakage as determined by the damp washcloth, followed by the joints of the tubes of the delivery system and, finally, the system's exhaust filter. Contamination readings from face masks worn by technical personnel during the lung ventilation studies were slightly greater than 0.05 mR/hr. CONCLUSION The findings support trace levels of contamination to both the technologist and room while performing 99mTc DTPA aerosol ventilation studies. Comparative data using the two delivery systems revealed little difference in sources of leakage and little variation in contamination measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reverse mismatched ventilation-perfusion pulmonary imaging with accumulation of technetium-99m-DTPA in a mucous plug in a main bronchus: a case report.

The phenomenon of reverse mismatched ventilation-perfusion on pulmonary scintigraphy is a fairly common occurrence. We present a patient who was experiencing decreasing oxygen saturation and had a reverse mismatched ventilation-perfusion imaging pattern associated with radiotracer retention in a main bronchus. Technetium-99m-DTPA aerosol lung imaging showed tracer retention in the trachea and r...

متن کامل

Aerosol delivery during high frequency jet ventilation: an MRI evaluation.

BACKGROUND We have previously demonstrated aerosol delivery during conventional and high frequency oscillatory (HFOV) ventilation using magnetic resonance imaging (MRI) in piglets. There are no reports on aerosol delivery during high frequency jet ventilation (HFJV). OBJECTIVE To compare delivery of aerosolized gadopentetate dimeglumine (Gd-DTPA) in 3 neonatal ventilator circuits: convention...

متن کامل

Absorptive clearance of DTPA as an aerosol-based biomarker in the cystic fibrosis airway.

Biomarkers providing in vivo quantification of the basic elements of cystic fibrosis (CF) lung disease are needed. A study was performed to determine whether the absorption of a small radiolabelled hydrophilic molecule (Indium-111 (In-)DTPA) would be increased in CF airways. DTPA clearance has been used previously to assess epithelial permeability and may also be useful for quantifying liquid a...

متن کامل

Technetium-99m-DTPA aerosol scintigraphy in amiodarone induced pulmonary toxicity in comparison with Ga-67 scintigraphy.

Amiodarone hydrochloride, which is used in life-threatening cardiac tachyarrhythmia, has been known to cause amiodarone induced pulmonary toxicity (AIPT) as a complication. In this study we aimed to investigate the clinical value of technetium-99m diethylene triamine penta-acetic acid (DTPA) aerosol lung scintigraphy in patients with AIPT in comparison with gallium-67 (Ga-67) scan. The study gr...

متن کامل

Ventilation-perfusion SPECT/CT in Diagnosing Swyer-James (MacLeod) Syndrome

We present the characteristics of a ventilation-perfusion scan correlating to both planar and single photon emission computed tomography and computed tomography (SPECT/CT) images of the lungs in a patient with SwyerJames (MacLeod) syndrome. A Tc-99m MAA lung perfusion scan was recorded with multiple projections and SPECT/CT. In the ventilation scan, initially dynamic acquisition of aerosol Tc-9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1998