Evaluation of accelerated solvent extraction for butyltin speciation in PACS-2 CRM using double-spike isotope dilution-GC/ICPMS.

نویسندگان

  • Jorge Ruiz Encinar
  • Pablo Rodriguez-González
  • Julio Rodriguez Fernandez
  • J Ignacio Garcia Alonso
  • Sergi Díez
  • Josep M Bayona
  • Alfredo Sanz-Medelt
چکیده

Pressurized liquid extraction using the accelerated solvent extractor (Dionex ASE 200) has been evaluated for the determination of mono-, di- and tributyltin (MBT, DBT, and TBT, respectively) in PACS-2 certified reference material. A double-enriched spike containing 119Sn-enriched MBT and TBT and 118Sn-enriched DBT allowed for the simultaneous determination of the three butyltin species and the factors governing species interconversion. The stability of the spike was evaluated by reverse isotope dilution experiments covering more than one year with satisfactory results. Quantitative recoveries using ASE for TBT and DBT were obtained at temperatures above 110 degrees C. The effect of the extraction time and number of static cycles was evaluated. Results suggest that extraction efficiency was quantitative with extraction times as low as 10 min for all butyltin species at 110 degrees C. Decomposition reactions were only detected at the higher temperatures assayed (140 and 175 degrees C) and that was only for the degradation of DBT to MBT (approximately 4%). The results found for MBT were approximately 25% higher than the certified value for the PACS-2 sediment reference material in agreement with previous results obtained by ultrasonic and microwave assisted extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Butyltin Compounds in Environmental Samples by Isotope Dilution GC-MS Application

A GC-MS with electron impact ionization was used for the development of a speciation method for the simultaneous determination of monobutyl-, dibutyl-, and tributyltin in environmental samples (waters, sediments, and biota). The method is based on the use of a mixed spike containing Sn-enriched monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) for isotope dilution analysis. The mixed ...

متن کامل

Certification of butyltins and phenyltins in marine sediment certified reference material by species-specific isotope-dilution mass spectrometric analysis using synthesized 118Sn-enriched organotin compounds

A new marine sediment certified reference material, NMIJ CRM 7306-a, for butyltin and phenyltin analysis has been prepared and certified by the National Metrological Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Candidate sediment material was collected at a bay near industrial activity in Japan. After air-drying, sieving, and mixing the...

متن کامل

Assessment of mercury speciation in feathers using species-specific isotope dilution analysis.

Seabirds are considered as effective sentinels of environmental marine contamination and their feathers are extensively used as non-lethal samples for contaminant biomonitoring. This tissue represents the main route for mercury (Hg) elimination in seabirds and contains predominantly methylmercury (MeHg). In this work, we developed a robust analytical technique for precise and accurate simultane...

متن کامل

Methylmercury measurement in whole blood by isotope-dilution GC-ICPMS with 2 sample preparation methods.

BACKGROUND Despite its known toxicity, methylmercury is rarely measured directly in clinical studies; instead, conclusions are based on total mercury measurements. We have developed isotope-dilution-based methods for methylmercury-specific analysis of whole blood by coupled gas chromatography-inductively coupled plasma mass spectrometry (GC-ICPMS). METHODS We analyzed animal and human blood s...

متن کامل

Application of isotopically labeled methylmercury for isotope dilution analysis of biological samples using gas chromatography/ICPMS.

An isotope dilution (ID) procedure for the determination of methylmercury (MMHg) in biological samples using an inductively coupled plasma mass spectrometer as detector after the capillary gas chromatographic separation (CGC/ICPMS) has been developed. For the first time, open-focused-microwave pretreatment has been used in conjunction with ID. Optimum conditions for the measurement of isotope r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 20  شماره 

صفحات  -

تاریخ انتشار 2002