Inappropriate Shocks in Patients with ICDs: Single Chamber versus Dual Chamber
نویسندگان
چکیده
BACKGROUND Despite the technological evolution of the implantable defibrillator, one of the questions that remains is the possible benefit of the dual chamber versus single chamber implantable cardioverter defibrillator (ICD) in reducing inappropriate shocks. OBJECTIVE To evaluate which type of device provides fewer inappropriate shocks (dual chamber versus single chamber) in patients with implantable cardioverter defibrillators (ICDs). METHODS Meta-analysis of randomized studies published in the literature comparing dual-chamber implantable cardioverter defibrillators to single chamber devices which have been known to cause, as an evaluated endpoint, inappropriate shocks. RESULTS The dual-chamber implantable cardioverter showed no benefit in reducing the number of inappropriate shocks. In fact, the opposite was shown. In the analysis of fixed effects, the association tended to favor single-chamber implantable cardioverter defibrillators (OR = 1.53, CI 95%: 0.91-2.57), despite the absence of statistical significance (p = 0.11). We highlight the heterogeneity observed in the results (I² = 53%), which motivated a replication of the analysis using a model of random effects. However, significant differences remained in the occurrence of inappropriate shocks in both groups (OR = 1.1, 95% CI: 0.37-3.31; p = 0.86). To complement the analysis, we proceeded to perform sensitivity analysis, which showed that the exclusion of a study resulted in the lowest heterogeneity observed (I²=24%) and the association with inappropriate shocks significantly favored the single chamber cardiodefibrillator (OR = 1.91; 95% CI: 1.09-3.37; p = 0.27). CONCLUSIONS It was determined that there was no clear evidence of superiority of any of the devices evaluated.
منابع مشابه
Relation between detection rate and inappropriate shocks in single versus dual chamber cardioverter-defibrillator – an analysis from the OPTION trial
The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ alg...
متن کاملDual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.
BACKGROUND Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. METHODS AND RESULTS Subjects with a clinical indication for ICD (n=400) a...
متن کاملReduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.
OBJECTIVES The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients. BACKGROUND The use of dual-chamber ICDs potentially allows be...
متن کاملComparison of Inappropriate Shocks and Other Health Outcomes Between Single‐ and Dual‐Chamber Implantable Cardioverter‐Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter‐Defibrillators
BACKGROUND In US clinical practice, many patients who undergo placement of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death receive dual-chamber devices. The superiority of dual-chamber over single-chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compar...
متن کاملInappropriate cardioverter-defibrillator discharge continues to be a major problem in clinical practice.
BACKGROUND The purpose of this study was to determine the rate and causes of inappropriate rhythm detection, and to compare adequacy of ventricular arrhythmia detection by single-chamber and dual-chamber cardioverter-defibrillators (ICD). METHODS We evaluated 190 patients (age 57.2 +/- 11.2 years) with ICD. FOLLOW-UP 34.3 +/- +/- 22 months. Dual-chamber ICD was used in 54 patients. RESULT...