Comparative study of periapical radiographic techniques with apex locator for endodontic working length estimation: an ex vivo study.

نویسندگان

  • Vaishali Parekh
  • Chirag Taluja
چکیده

BACKGROUND Accurate assessment of working length determines the success and prognosis of an endodontic treatment outcome. Various methods are used in determining the working length. AIM Compare the measurements of the apex locator and radiographic technique to determine working length. METHODS An ex vivo study was conducted on 20 patients having intact single straight root canal. Only premolars were taken in the study. After doing coronal flaring and irrigation, the radiographic length was determined with an aid of a k-type file and electronic length (EL-Root-ZX) 3rd generation apex locator. After extraction of all the premolars, stereomicroscope was further used to confirm and compare radiographic and electronic apex locator. RESULTS A mean value of 0.5430 ± 0.5741 mm was observed among radiographic techniques. A mean value of 0.4240 ± 0.4587 mm was observed among apex locator techniques. T-test revealed, no significant difference between the two techniques was observed (p = 0. 615). 'Two tailed' t-test revealed intragroup significance both techniques for determining the working length. CONCLUSION The distance of the apical foramen to the tip of the file: A mean value of 0.4240 ± 0.4587 mm with apex locator technique was observed. Working length of apex locator was more in comparison to radiographic technique. No significant difference between the two techniques was observed (p = 0. 615). Intragroup significance among both techniques for determining the working length was also observed. However, a further study incorporating a larger sample size and utilization of both techniques of working length determination on the same tooth has to be conducted. CLINICAL SIGNIFICANCE Combining the apex locator technique and radiographic technique for determination of working length would yield more accurate working length.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study

BACKGROUND Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using Direct Digita...

متن کامل

Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study

INTRODUCTION The purpose of this clinical study was to compare the accuracy of working length (WL) determination using cone-beam computed tomography (CBCT), conventional periapical radiographies and electronic apex locator. METHODS AND MATERIALS This study was conducted during root canal treatment of 19 patients with a total of 30 single-rooted teeth diagnosed with apical periodontitis. After...

متن کامل

Accurate Measurement of Canal Length during Root Canal Treatment: An In Vivo Study

Objectives: to assess the consistency and accuracy of Electronic Apex Locator (EAL) (root ZXII) in individual canals and its association with other clinical variables. study Design: cross-sectional study. Place of study: Dental section of the Aga Khan University Hospital, Karachi, Pakistan. Materials and Methods: Working length was measured by EAL in 180 patients requiring endodontic therapy in...

متن کامل

Endodontic treatment failure consecutive to unsystematic radiographic examination.

This case report describes the endodontic therapy on a three-rooted mandibular first molar. The initial endodontic treatment was carried out after misreading preoperative periapical radiograph. Moreover, the working length was determined only with the apex locator. So, the additional disto-lingual root left unidentified and remained untreated, failing the treatment. A thorough radiographic exam...

متن کامل

Comparative analysis of the electronic and radiographic determination of root canal length of primary molars– an ex vivo study

Correspondence to: Lucineide de Melo Santos Faculdade de Odontologia-FOUFAL Av. Lourival Melo Mota, s/n, Tabuleiro do Martins Maceió AL, CEP: 57072-970 E-mail: [email protected] Abstract Aim: ́ To evaluate comparatively the radiographic and electronic root canal length determination in primary molars. Methods: 128 canals from 66 primary molars were selected. The root of each tooth was cut open ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2011