International Nosocomial Infection Control Consortium report, data summary for 2002-2007, issued January 2008.

نویسندگان

  • Victor D Rosenthal
  • Dennis G Maki
  • Ajita Mehta
  • Carlos Alvarez-Moreno
  • Hakan Leblebicioglu
  • Francisco Higuera
  • Luis E Cuellar
  • Naoufel Madani
  • Zan Mitrev
  • Lourdes Dueñas
  • Josephine Anne Navoa-Ng
  • Humberto Guanche Garcell
  • Lul Raka
  • Rosalía Fernández Hidalgo
  • Eduardo A Medeiros
  • Souha S Kanj
  • Salisu Abubakar
  • Patricio Nercelles
  • Ricardo Diez Pratesi
چکیده

We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from 2002 through 2007 in 98 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance System (NNIS) definitions for device-associated health care-associated infection, we collected prospective data from 43,114 patients hospitalized in the Consortium's hospital ICUs for an aggregate of 272,279 days. Although device utilization in the INICC ICUs was remarkably similar to that reported from US ICUs in the CDC's National Healthcare Safety Network, rates of device-associated nosocomial infection were markedly higher in the ICUs of the INICC hospitals: the pooled rate of central line-associated bloodstream infections (CLABs) in the INICC ICUs, 9.2 per 1000 CL-days, is nearly 3-fold higher than the 2.4-5.3 per 1000 CL-days reported from comparable US ICUs, and the overall rate of ventilator-associated pneumonia was also far higher, 19.5 vs 1.1-3.6 per 1000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 6.5 versus 3.4-5.2 per 1000 catheter-days. Most strikingly, the frequencies of resistance of Staphylococcus aureus isolates to methicillin (MRSA) (80.8% vs 48.1%), Enterobacter species to ceftriaxone (50.8% vs 17.8%), and Pseudomonas aeruginosa to fluoroquinolones (52.4% vs 29.1%) were also far higher in the Consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 14.3% (CLABs) to 27.5% (ventilator-associated pneumonia).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

National Healthcare Safety Network (NHSN) Report, data summary for 2006 through 2007, issued November 2008.

This report is a summary of device-associated and procedure-associated module data collected and reported by hospitals participating in the National Healthcare Safety Network (NHSN) from January 2006 through December 2007 as reported to the NHSN by March 24, 2008. This report updates previously published device-associated module data from NHSN and surgical site infection (SSI) rate data from th...

متن کامل

International Nosocomial Infection Control Consortium (INICC) report, data summary for 2003-2008, issued June 2009.

We report the results of the International Infection Control Consortium (INICC) surveillance study from January 2003 through December 2008 in 173 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) US National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillanc...

متن کامل

National Healthcare Safety Network (NHSN) Report, data summary for 2006, issued June 2007.

This report is a summary of device-associated in­ fections data collected and reportedbyhospitals partici­ pating in the National Healthcare Safety Network (NHSN) from January through December 2006. This report updates previously published data from the National Nosocomial Infections Surveillance (NNIS) system. The NHSN was established in 2005 to integrate and supersede 3 legacy surveillance sy...

متن کامل

International Nosocomial Infection Control Consortium (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module.

We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care...

متن کامل

National Healthcare Safety Network (NHSN) report: data summary for 2006 through 2008, issued December 2009.

This report is a summary of Device-Associated (DA) and Procedure-Associated (PA) module data collected and reported by hospitals and ambulatory surgical centers participating in the National Healthcare Safety Network (NHSN) from January 2006 through December 2008 as reported to the Centers for Disease Control and Prevention (CDC) by July 6, 2009. This report updates previously published DA and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of infection control

دوره 36 9  شماره 

صفحات  -

تاریخ انتشار 2008