Suture pull-through insertion of graft donor in Descemet stripping automated endothelial keratoplasty: Results of 4-year follow-up

نویسندگان

  • Vincenzo Sarnicola
  • Chiara Millacci
  • Enrica Sarnicola
  • Caterina Sarnicola
  • Francesco Sabatino
  • Andrew Ruggiero
چکیده

PURPOSE To report our clinical experience and 4-year follow-up results of Descemet stripping automated endothelial keratoplasty (DSAEK) with the suture pull-through insertion technique. METHODS This is a retrospective study of 195 eyes in which a posterior lamellar keratoplasty was performed between 2007 and 2011. The insertion of a folded donor lenticule was performed with a double-armed 10-0 suture using a straight transchamber needle and half-circle needle. Endothelial cell density was measured annually up to 4 years after the surgery, and cell loss was calculated based on the median preoperative donor endothelial cell density. Postoperative complications, primary graft failure, pupillary block, and dislocation of the donor tissue were assessed. RESULTS All patients underwent uncomplicated DSAEK. Data were available for 195 eyes (100%) at 1 year, 186 eyes (95.3%) at 2 years, 176 eyes (90.2%) at 3 years, and 160 eyes (82%) at 4 years. Median preop-erative donor endothelial cell density was 2688 cells/mm2 [interquartile range (IQR) 207.5 cells/mm2], which decreased by 27% at 1 year (1956 cells/mm2, IQR 264.8 cells/mm2), 31% at 2 years (1855 cells/mm2, IQR 320.5 cells/mm2), 35% at 3 years (1756.5 cells/mm2, IQR 306.5 cells/mm2), and 36% at 4 years (1709.5 cells/mm2, IQR 288,0 cells/mm2). Nine patients (4.6%) had a dislocation of donor tissue; all were successfully reattached with a second air injection. Only three eyes (1.5%) developed graft failure. Pupillary block was present in 15 eyes (7.7%). CONCLUSION DSAEK with suture pull-through insertion of donor graft represents a simplified and safe technique that has endothelial cell loss comparable with other techniques and low rates of intraoperative and postoperative complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suturing Technique to Promote Graft Attachment in Challenging Cases of Descemet Stripping Endothelial Keratoplasty

Aims: To describe a technique that uses a transcorneal fixation suture for graft attachment in endothelial keratoplasty in high-risk for graft dislocation eyes. Materials and Methods: Case series included 12 eyes of 12 patients who underwent Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in the presence of high risk for graft dislocation factors. We describe a surgical technique ...

متن کامل

Suture Pull-Through Insertion Techniques for Descemet Stripping Automated Endothelial Keratoplasty in Chinese Phakic Eyes: Outcomes and Complications

PURPOSE To investigate the outcomes and complications of suture pull-through insertion techniques for Descemet stripping automated endothelial keratoplasty (DSAEK) in Chinese phakic eyes. PATIENTS AND METHODS Retrospective case series. Included in the study were all Chinese patients with phakic eyes who underwent DSAEK at Peking University Third Hospital from August 2008 to August 2011. All o...

متن کامل

Histologically proven epithelial ingrowth in failed Descemet stripping automated endothelial keratoplasty (DSAEK) managed by repeat DSAEK

PURPOSE To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. METHODS A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant ...

متن کامل

Pull-Through Insertion Technique for Descemet Stripping Automated Endothelial Keratoplasty (DSAEK): Graft Survival and Endothelial Cell Loss after 1 Year in 100 Eyes

Aim: To assess graft survival and endothelial cell loss after DSAEK using a pull-through insertion technique with incision width of 3.2mm or 4.1mm. Methods: The medical records of 100 consecutive eyes that had undergone DSAEK at the Turin University Ophthalmology Institute between November 2007 and April 2010 were reviewed. Surgery was performed by a single surgeon and included: descemethorexis...

متن کامل

Descemet stripping automated endothelial keratoplasty using cultured corneal endothelial cells in a rabbit model.

OBJECTIVE To investigate the feasibility of Descemet stripping automated endothelial keratoplasty (DSAEK) using cultured human corneal endothelial cells (HCECs) in an animal model. METHODS Descemet stripping automated endothelial keratoplasty grafts were produced by seeding cultured HCEC suspensions onto human corneal stromal discs. Three insertion techniques were assessed in an ex vivo model...

متن کامل