Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable chemicals and cleaning products. It must be possible to reprocess the dispenser and all of its permanent parts by applying machine based thermal disinfection at an A(0)-value of minimum 60 (e.g. 80°C/1 minute). Automatically portioning dispensers shall not fail during 200 hubs. The maximal allowed failure rate shall not exceed 1% (2 out of 200 consecutive hubs). A dispenser used for alcohol based hand rubs must allow keeping the alcohol concentration constant over a time period of 3 months. The maximum acceptable decrease in the concentration of the alcohol shall not exceed 5%. Liquid soap and hand rub dispensers with single-use pumps, ideally already mounted on the cartridge and to be discharged with the empty cartridge, are preferable. If pumps are used on the next consecutive cartridge, the manufacturer must provide the user with a detailed introduction for cleansing and reprocessing before further use. Because of forensic reasons it is recommended to place a good readable sign on the dispenser indicating e.g. "Apply alcohol based hand rubs only on the hand! Do not drink, avoid spraying into the eye or application on mucous membranes". It is regarded as an additional benefit, if the dispenser is able to document the consumption of hand rub or the frequency of hubs either mechanically or electronically.
منابع مشابه
Low frequency of fires from alcohol-based hand rub dispensers in healthcare facilities.
We administered a web-based questionnaire to SHEA, APIC, and EIN members to assess the frequency of fires associated with alcohol-based hand rub (ABHR) dispensers in healthcare settings. None of the 798 responding facilities using ABHRs reported a dispenser-related fire; 766 facilities had accrued an estimated 1,430 hospital-years of ABHR use.
متن کاملImplementing AORN recommended practices for hand hygiene.
This article focuses on implementing the revised AORN "Recommended practices for hand hygiene in the perioperative setting." The content of the document has been expanded and reorganized from the previous iteration and now includes specific activity statements about water temperature, water and soap dispensing controls, the type of dispensers to use, paper towel dispenser requirements, placemen...
متن کاملHand hygiene for the prevention of nosocomial infections.
BACKGROUND The WHO regards hand hygiene as an essential tool for the prevention of nosocomial infection, but compliance in clinical practice is often low. METHODS The relevant scientific literature and national and international evidence-based recommendations (Robert Koch Institute [Germany], WHO) were evaluated. RESULTS Hygienic hand disinfection has better antimicrobial efficacy than hand...
متن کاملAssessing the optimal location for alcohol-based hand rub dispensers in a patient room in an intensive care unit
BACKGROUND The introduction of alcohol-based hand rub dispensers has had a positive influence on compliance of healthcare workers with the recommended guidelines for hand hygiene. However, establishing the best location for alcohol-based hand rub dispensers remains a problem, and no method is currently available to optimize the location of these devices. In this paper we describe a method to de...
متن کاملمقایسه اثر شستن دست با صابون و مایع الکلی بدون آب (Hand Rub) در پاک سازی آلودگی میکروبی دست پرستاران بیمارستانی
Introduction: Hospital acquired infections recognize as an important risk factor in health care. In this regard health care and hand hygiene is the first step in controlling the infections. This study, carried out with the aim of comparing the effect of hand washings in the usual way with disinfectants without water in microbial contamination of the hospitals hand nurses. Material and Method...