Clinical accuracy of continuous hemoglobin oxygen saturation monitoring devices.

نویسندگان

  • G Z Bolen
  • G E Anderson
  • J R Huddleson
  • J B Riley
  • R G Sutton
  • D G Bishop
چکیده

Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 Co-Oximeter. Fifty-one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: table: see text. The Accusat was found to be a statistically more accurate means of monitoring hemoglobin oxygen saturations during cardiopulmonary bypass than the ABL4 and the OxySat. All devices had significant correlation with the control and with each other.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SCIENTIFIC PRESENTATION AWARD Clinical Accuracy of Continuous Hemoglobin Oxygen Saturation Monitoring Devices

-----------------Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and the Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 CoOximeter. Fifty one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: TABLE...

متن کامل

Predicting Transitions in Oxygen Saturation Using Phone Sensors

Introduction: Widespread availability of mobile devices is revolutionizing health monitoring. Smartphones are ubiquitous, but it is unknown what vital signs can be monitored with medical quality. Oxygen saturation is a standard measure of health status. We have shown phone sensors can accurately measure walking patterns. Subjects and Methods: Twenty cardiopulmonary patients performed 6-min walk...

متن کامل

In vitro evaluation of continuous mixed venous oxygen saturation and hematocrit monitors.

Four venous hemoglobin oxygen saturation monitors, two of which provide hemoglobin monitoring, were evaluated and compared to a performance standard (control) during cardiopulmonary bypass (CPB). The CDI 100 Hematocrit/Saturation Monitor, CDI 400, Cobe Hematocrit/Saturation Monitor, and the Baxter Bentley OxySat values were compared to the Radiometer Copenhagen OSM3 Hemoximeter and the Damon In...

متن کامل

Non-invasive approaches to tissue bioenergetics.

It is clear that continuous light affords a very limited window of opportunity for quantitative spectrophotometry of brain tissue. However, the number of qualitative applications which are available exemplify how this extremely simple technique can be applied to important medical problems. The development of devices which can measure directly the oxygen saturation of the brain is more complicat...

متن کامل

Correlation between Pulse Oximetry Oxygen Saturation (SpO2) and Measured Arterial Oxygen Saturation (SaO 2 ) and Arterial Oxygen Tension (PaOz) in Neonates

=Abstract=Pulse oximetry has recently been introduced as a method for continuous and non-invasive transcutaneous monitoring of arterial oxygen saturation in neonates. The purpose of our study was to determine the reliability, accuracy, and practicability of pulse oximetry for monitoring arterial oxygenation in sick newborn infants. Pulse oximetry oxygen saturation values (SpO2) were compared wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1990