An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
نویسندگان
چکیده
The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased proportionally with the field size from approximately 10% to 30%. The measurements were also taken using four common detectors: TLD chips, PFD dosimeter, parallel-plate and cylindrical ionization chamber, and compared with MC simulated data, which served as the gold standard in our study. The surface doses obtained from each detector were derived from the extrapolation of the measured depth doses near the surface and were all found to be higher than that of the MC simulation. The lowest and highest over-responses in the surface dose measurement were found with the TLD chip and the CC13 cylindrical ionization chamber, respectively. Increasing the field size increased the percentage surface dose almost linearly in the various dosimeters and also in the MC simulation. Interestingly, the use of the CC13 ionization chamber eliminates the high gradient feature of the depth dose near the surface. The correction factors for the measured surface dose from each dosimeter for square field sizes of between 5 × 5 and 20 × 20 cm(2)are introduced.
منابع مشابه
Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...
متن کاملThe effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملMonte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...
متن کاملMonte Carlo estimation of electron contamination in a 18 MV clinical photon beam
Background: The electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. The detailed characteristics of contaminant electrons are presented for different field sizes and cases. Materials and Methods: The Monte Carlo code, MCNPX, has been used to simulate 18 MV photon beam from a Varian Linac-2300 accelerator. All dose measurements were car...
متن کاملMonte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...