Diagnosing infection in the failed joint replacement: a comparison of coincidence detection 18F-FDG and 111In-labeled leukocyte/99mTc-sulfur colloid marrow imaging.

نویسندگان

  • Charito Love
  • Scott E Marwin
  • Maria B Tomas
  • Eugene S Krauss
  • Gene G Tronco
  • Kuldeep K Bhargava
  • Kenneth J Nichols
  • Christopher J Palestro
چکیده

UNLABELLED The objectives of this study were to investigate (18)F-FDG imaging, using a coincidence detection system, for diagnosing prosthetic joint infection and to compare it with combined (111)In-labeled leukocyte/(99m)Tc-sulfur colloid marrow imaging in patients with failed lower extremity joint replacements. METHODS Fifty-nine patients--with painful, failed, lower extremity joint prostheses, 40 hip and 19 knee--who underwent (18)F-FDG, labeled leukocyte, and bone marrow imaging, and had histopathologic and microbiologic confirmation of the final diagnosis, formed the basis of this investigation. (18)F-FDG images were interpreted as positive for infection using 4 different criteria: criterion 1: any periprosthetic activity, regardless of location or intensity; criterion 2: periprosthetic activity on the (18)F-FDG image, without corresponding activity on the marrow image; criterion 3: only bone-prosthesis interface activity, regardless of intensity; criterion 4: semiquantitative analysis--a lesion-to-background ratio was generated, and the cutoff value yielding the highest accuracy for determining the presence of infection was determined. Labeled leukocyte/marrow images were interpreted as positive for infection when periprosthetic activity was present on the labeled leukocyte image without corresponding activity on the marrow image. RESULTS Twenty-five (42%) prostheses, 14 hip and 11 knee, were infected. The sensitivity, specificity, and accuracy of (18)F-FDG, by criterion, were as follows: criterion 1: 100%, 9%, 47%; criterion 2: 96%, 35%, 61%; criterion 3: 52%, 44%, 47%; criterion 4: 36%, 97%, 71%. The sensitivity, specificity, and accuracy of labeled leukocyte/marrow imaging were 100%, 91%, and 95%, respectively. WBC/marrow imaging, which was more accurate than any of the (18)F-FDG criteria for all prostheses, as well as for hips and knees separately, was significantly more sensitive than criterion 3 (P < 0.001) and criterion 4 (P < 0.001) and was significantly more specific than criterion 1 (P < 0.001), criterion 2 (P < 0.001), and criterion 3 (P < 0.001). CONCLUSION Regardless of how the images are interpreted, coincidence detection-based (18)F-FDG imaging is less accurate than, and cannot replace, labeled leukocyte/marrow imaging for diagnosing infection of the failed prosthetic joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dichotomous Indium-111 labeled leukocyte scan findings while evaluating osteomyelitis in a failed mandibular graft

Markedly elevated111 In labeled leukocyte activity suggestive of acute osteomyelitis was observed in a region of a composite mandibular allograft that was photon deficient on 99mTc MDP bone scintigraphy. This finding was later confirmed by surgical pathology. The patient was treated with intravenous antibiotics and returned two months later with persistent bone infection. The foHow-up thr...

متن کامل

Tc-99m Labeled HMPAO white Blood Cell Scintigraphy in a patient with Hip Prosthesis

Background The ability to follow the distribution and migration of biologically active cells in human is essential for the development of cell-based therapies and diagnostics. Nuclear medicine imaging is widely applied in clinic as an attractive technique for in vivo WBC and stem cell tracking. The aim of this study was to evaluate prosthesis infection of a 51 years old man with previous histo...

متن کامل

Clinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy

Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...

متن کامل

Use of Marrow Scintigraphy to Confirm Compensatory Marrow Rather than Active Myeloma

We read with much interest the article entitled “Use of marrow scintigraphy to confirm compensatory marrow rather than active myeloma” by Bartel et al. published in your esteemed journal. This article enlightens us regarding a very interesting case of false positive fluorodeoxyglucose (FDG) uptake in a follow‐up case of multiple myeloma (MM). The authors in the present case have very nicely des...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 11  شماره 

صفحات  -

تاریخ انتشار 2004