PEF analysis requiring shorter records for occupational asthma diagnosis.

نویسندگان

  • Vicky C Moore
  • Maritta S Jaakkola
  • Cedd B S G Burge
  • Charles F Pantin
  • Alastair S Robertson
  • Arun Dev Vellore
  • P Sherwood Burge
چکیده

BACKGROUND The Oasys programme plots serial peak expiratory flow (PEF) measurements and produces scores of the likelihood that the recordings demonstrate occupational asthma. We have previously shown that the area between the mean workday and rest day PEF curves [the area between the curves (ABC) score] has a sensitivity of 69% and specificity of 100% when plotted from waking time using a cut-off score of 15 l/min/h. AIMS To investigate the minimum data requirements to maintain the sensitivity and specificity of the ABC score. METHODS A total of 196 sets of measurements from workers with occupational asthma confirmed by methods other than serial PEFs and 206 records from occupational and non-occupational asthmatics who were not at work at the time of PEF monitoring were analysed according to their mean number of readings per day. Measurements from work and rest days were sequentially removed separately and the ABC score calculated at each reduction. The sensitivity and specificity of the ABC score (using a cut-off of 15 l/min/h) was calculated for each duration. RESULTS Two-hourly measurements (approximately 8 readings per day) with eight workdays and three rest days had 68% sensitivity and 91% specificity for occupational asthma diagnosis. As readings decreased to or=15 workdays were required to provide a specificity above 90%. CONCLUSIONS To be sensitive and specific in the diagnosis of occupational asthma, the ABC score requires 2-hourly PEF measurements on eight workdays and three rest days. This is a short assessment period that should improve patient compliance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of occupational asthma from time point differences in serial PEF measurements.

BACKGROUND The diagnosis of occupational asthma requires objective confirmation. Analysis of serial measurements of peak expiratory flow (PEF) is usually the most convenient first step in the diagnostic process. A new method of analysis originally developed to detect late asthmatic reactions following specific inhalation testing is described. This was applied to serial PEF measurements made ove...

متن کامل

Peak expiratory flow analysis in workers exposed to detergent enzymes.

AIMS To study serial peak expiratory flow (PEF) responses in a group of symptomatic detergent enzyme-exposed workers. METHODS Workers were recruited from a biological detergent formulating and packaging company. Those with occupational asthma symptoms and/or specific IgE to a detergent enzyme were asked to complete 2 hourly PEF measurements for 4 weeks. Outputs from the Oasys program (Oasys s...

متن کامل

Serial PEF measurement is superior to cross-shift change in diagnosing occupational asthma.

Cross-shift measurements of peak expiratory flow (PEF) are commonly employed in the diagnosis of occupational asthma, although evidence for this approach is lacking. The current paper presents an evaluation of the technique. Mean changes in PEF across morning/day shifts were compared between workers with occupational asthma, confirmed using specific challenge testing, and non-working asthmatics...

متن کامل

Development of OASYS-2: a system for the analysis of serial measurement of peak expiratory flow in workers with suspected occupational asthma.

BACKGROUND Serial peak expiratory flow (PEF) measurement is usually the most appropriate first step in the confirmation of occupational asthma. Visual assessment of the plotted record is more sensitive and specific than statistical methods so far reported. The use of visual analysis is limited by lack of widespread expertise in the methods. A computer assisted diagnostic aid (OASYS-2) has been ...

متن کامل

Improving the quality of peak flow measurements for the diagnosis of occupational asthma.

INTRODUCTION Serial measurements of peak expiratory flow (PEF) are recommended in the evidence-based review list as the first stage in objective confirmation of occupational asthma. Different centres have reported widely different success in obtaining records of sufficient data quantity for diagnosis. We investigated different methods of instruction and determined the return rate and quality of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational medicine

دوره 59 6  شماره 

صفحات  -

تاریخ انتشار 2009