Changes in renal function in valvular and coronary patients.
نویسندگان
چکیده
ETCO2 increased to 45 mmHg. We could not pass a suction catheter beyond a distance of 24 cm from the entrance of the tracheal tube. Using a fibrescope, we could see the appearance of a meniscus and a crescent shape on the inner wall. Because of the prone position, we could not change the tube but managed to maintain ventilation, saturation and ETCO2 within the normal range by a change of ventilatory mode for the remaining 5 h of the procedure. After returning to the supine position at the end of the operation, we extubated the patient and her self-respiration was good. Unfortunately, we found mild left lower lobe atelectasis postoperatively, which responded to physiotherapy. Her lung condition had returned to normal without complication by the second postoperative day. Examination of the reinforced tube showed two internal blisters, one at the entrance and one at 24 cm from the entrance. Examination using a rigid fiberscope and computed tomography (Fig. 1) showed a dissection of the inner layer of the tube. The dissection had caused longitudinal blisters of 2.8 and 4.2 cm length and reduction of the internal diameter to 3.5 and 2.9 mm at the proximal and distal parts, respectively. We assumed that the damage of the tube was caused by faulty manufacture. However, we subsequently discovered that the cause was multiple reuse of the single-use tube. Similar complications have been reported during anaesthesia with use of N2O [2,3] or even without N2O [4], exposure of heat, ethylene oxide [4–6] and gluteraldehyde solution [6] and stretching of a reinforced endotracheal tube [6]. The tube in this case had been cleaned after each use with hypochlorous acid (Medilox solution; Hicro-S, Soosan GIC Co Ltd, Seoul, Korea) after ultrasonic cleansing for 30 min. We should bear in mind that repeated reuse of reinforced endotracheal tubes that are designed for single use is unwise.
منابع مشابه
Correlation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome
Background and Objectives: The aim of this study was to survey the relationship between the level of creatinine,cardiac troponins serum and the function of the left ventricle in patients with kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample was150 patients with nondialysis chronic kidney disease without acute coronary syndrome, hospitalized at I...
متن کاملA Propensity Score Analysis of Renal Dysfunction in Patients after On-Pump and Off-Pump Coronary Artery Bypass Surgery
INTRODUCTION- Cardiovascular disease has emerged as a major health burden worldwide with coronary artery disease [CAD] causing highest mortality and morbidity. Coronary revascularization is the preferred treatment for patients with multivessel CAD. Based on the application of cardiopulmonary bypass [CPB], Coronary revascularization can be on-pump [OPCAB] or off-pump [CABG].The CPB is known to h...
متن کاملComparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries
Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...
متن کاملAvoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting
Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...
متن کامل[Renal function during cardiac surgery with extracorporeal circulation].
BACKGROUND Patients with valvular heart disease are at high risk of acute renal failure after surgery with extracorporeal circulation. AIM To describe changes in renal function parameters during surgery with extracorporeal circulation in patients with valvular heart disease and compare them with those found in patients undergoing elective coronary surgery. MATERIAL AND METHODS Two groups of...
متن کاملبررسی میزان شیوع تنگی شریان کلیه به دنبال آنژیوگرافی عروق کرونر و عوامل مرتبط با آن در بیماران مبتلا به فشارخون کاندید آنژیوگرافی عروق کرونر در بیمارستان افشار یزد
Introduction: Renal artery stenosis is the most prevalent disease of renal artery and has an important role in making hypertension and renal atrophy. Since in previous researches, despite high frequency of risk of cardiovascular disease in Iran, there did not exist any general research investigating risk factors of coronary artery disease and incidence of contemporary renal artery stenisis, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of anaesthesiology
دوره 24 11 شماره
صفحات -
تاریخ انتشار 2007