Editorial Manager(tm) for Cornea Manuscript Draft Manuscript Number: CORNEA-D-06-00395R1 Title: COMPLICATED FLAP CREATION WITH FEMTOSECOND LASER AFTER RADIAL KERATOTOMY

نویسنده

  • Canan Asli Utine
چکیده

Purpose: To report a case of LASIK using Intralase® due to residual myopic astigmatism, 14 years after radial keratotomy. Methods: Thirty-nine years-old male patient who had undergone bilateral RK operation for myopic correction was admitted to Turkiye Hospital, for the correction of the residual refractive error in his left eye. The manifest refraction was -1.25(-3.00@175), UCVA was 20/50 and BCVA was 20/20 on left eye. The keratometric measurements were 38.40D@92o, 35.40D@2o. The central and thinnest pachymetry measurements by Orbscan were 582μ and 576μ, respectively. LASIK operation with femtosecond laser flap formation was planned for the left eye. Results: Intralase® lost suction during flap formation. After device control, flap could be formed at the same intracorneal plane. During flap lifting, RK incisions were separated and one of them progressed to the corneal center with the force applied by the blunt spatula. No sectoral piece separated completely from the flap. Excimer laser treatment and flap re-positioning could be done without any problem. Postoperatively, all RK incisions appeared to be well aligned. The iron deposits around the radial incision at the central cornea spared the optic axis. There was no haze or epithelial in-growth. Conclusions: This case showed that Intralase® does not have unique benefit as opposed to the mechanical keratome for post-RK eyes. We recommend that femtosecond laser flap formation should be regarded with great caution in post-RK eyes. The suction performance of the device should be checked before the procedure and flap lifting maneuvers should be very cautious. * Copyright Transfer Form Click here to download high resolution image * Copyright Transfer Form Click here to download high resolution image

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complicated flap creation with femtosecond laser after radial keratotomy.

PURPOSE To report a case of laser in situ keratomileusis (LASIK) that used the Intralase femtosecond laser 14 years after radial keratotomy (RK) for residual myopic astigmatism. METHODS A 39 year-old male patient had undergone a bilateral RK operation for myopic correction. The manifest refraction was -1.25 -3.00 x 175 D, with uncorrected visual acuity (UCVA) of 20/50 and best-corrected visua...

متن کامل

Rescue of Primary Incomplete Microkeratome Flap with Secondary Femtosecond Laser Flap in LASIK

For laser-assisted in situ keratomileusis (LASIK) retreatments with a previous unsuccessful mechanical microkeratome-assisted surgery, some surgical protocols have been described as feasible, such as relifting of the flap or the creation of a new flap and even the change to a surface ablation procedure (photorefractive keratectomy (PRK)). This case shows the use of femtosecond technology for th...

متن کامل

Flap management during LASIK after radial keratotomy.

To the Editor: Radial keratotomy (RK) can be effective in reducing low to moderate amounts of myopia. Occasionally, a patient will “under-respond” to the RK procedure and be left with significant residual myopia. The refractive surgeon may then be presented with a situation where the patient desires more myopic reduction, but the surgeon does not want to perform another RK (for fear of inducing...

متن کامل

Editorial Manager(tm) for Journal of Computational Physics Manuscript Draft Manuscript Number: Title: An Implementation of an Exact Finite Reduction Scheme for Semilinear Dirichlet Problems

An Implementation of an Exact Finite Reduction Scheme for Semilinear Dirichlet Problems Franco Cardin, a Alberto Lovison a and Mario Putti b aDipartimento di Matematica Pura ed Applicata Universit a degli Studi di Padova via Belzoni 7, I { 35131 Padova, Italy bDipartimento di Metodi e Modelli Matematici per le Scienze Applicate Universit a degli Studi di Padova via Belzoni 7, I { 35131 Padova, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007