Short-wavelength acuity: optical factors affecting detection and resolution of blue–yellow sinusoidal gratings in foveal and peripheral vision

نویسندگان

  • Roger S. Anderson
  • Esther Coulter
  • Margarita B. Zlatkova
  • Shaban Demirel
چکیده

Previous studies have indicated that peripheral achromatic grating resolution is limited by the sampling density of the neural array (sampling limited), and largely unaffected by large amounts of optical defocus and significant changes in luminance. Under certain conditions, peripheral short-wavelength sensitive (SWS) grating acuity is also sampling limited. We wished to determine how the sampling-limited nature of SWS-driven grating resolution was affected by changing optical defocus and stimulus luminance. Using SWS-cone isolation techniques, detection and resolution acuity were measured for sinusoidal gratings under varying levels of stimulus mean luminance and optical defocus in the fovea and at 20 degrees eccentricity. From 1.4 down to 0.3 cd/m(2) peripheral detection acuity was superior to resolution acuity, accompanied by observations of aliasing: there was little change in resolution performance throughout this range. For defocus up to 3-4 dioptres, peripheral detection acuity was superior to resolution but fell steadily: resolution performance remained flat throughout the same range. Unlike achromatic acuity, foveal resolution performance displayed some robustness to defocus but to a lesser degree than the periphery. Peripheral SWS-driven resolution remains sampling limited for large changes in stimulus luminance and optical defocus, and should thus be useful as a clinical test of SWS-driven ganglion cell density.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What limits detection and resolution of short-wavelength sinusoidal gratings across the retina?

Peripheral resolution acuity for achromatic gratings is known to be limited by the density of the underlying ganglion cell sampling array. After confirming isolation of the short-wavelength sensitive (SWS) system using chromatic adaptation methods, we wished to determine if resolution is limited by blue/yellow ganglion cell sampling (evidenced by a superiority of detection over resolution acuit...

متن کامل

Short-wavelength acuity: blue–yellow and achromatic resolution loss with age

Previous studies have indicated that peripheral resolution for achromatic gratings is sampling limited and directly related to the density of the underlying midget ganglion cell population. Previous studies by the authors have shown that peripheral resolution for blue-cone isolating gratings is also sampling limited, is robust to optical defocus and short-wavelength attenuation, and yields esti...

متن کامل

Misecellaneous

ABERRATION Amblyopia in astigmatic preschool children 43: 1081 Astigmatism in infant monkeys reared with cylindrical lenses 43: 2721 Comparison of the time courses of concomitant and nonconcomitant vertical phoria adaptation 43: 567 Disorders of vertical optokinetic nystagmus in patients with ocular misalignment 43: 347 Effects of stimulus size and luminance on oscillopsia in congenital nystagm...

متن کامل

Binocular summation for grating detection and resolution in foveal and peripheral vision

Peripheral monocular grating resolution has been shown to be limited by the sampling density of the underlying retinal ganglion cells. We wanted to determine if peripheral resolution is also sampling limited binocularly; and, if so, how great is any improvement in either detection or resolution when viewing binocularly? We measured detection and resolution acuity for sinusoidal gratings in fove...

متن کامل

The selective effect of optical defocus on detection and resolution acuity in peripheral vision.

Detection and resolution acuity was measured at 30 degrees in the periphery for sinusoidal gratings under differing amounts of optical defocus. Within the range -2.0 to +2.5 diopters defocus, detection acuity was higher than resolution acuity. As defocus increased, detection acuity decreased continuously but resolution acuity was little affected until around 2.0 diopters defocus. The results in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2003