Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes.
نویسندگان
چکیده
OBJECTIVE To compare the association between scanning laser polarimetry (SLP) retinal nerve fiber layer (RNFL) measurements and automated perimetry sensitivity using both SLP manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude and corneal polarization axis values. METHODS An SLP was modified to enable the measurement of corneal polarization magnitude and corneal polarization axis so that compensation for corneal birefringence could be corrected on a subject-specific variable basis. Seventy-three eyes from the University of California, San Diego, Diagnostic Innovations in Glaucoma Study with early glaucoma or suspected glaucoma (abnormal Swedish Interactive Threshold Algorithm [SITA] or full-threshold automated perimetry results and/or glaucomatous-appearing optic disc by consensus grading of stereoscopic optic disc photographs) (mean [SD] SITA mean deviation, -2.74 [3.71] dB; range, 1.72 to -14.72 dB) were included. Subjects were imaged with SLP using the manufacturer-assumed fixed corneal compensation values and subject-specific variable corneal compensation values and tested with SITA automated perimetry. Scanning laser polarimetry and SITA data were obtained within 3 months of each other. MAIN OUTCOME MEASURES The relationship between regional SLP RNFL measurements (24 parameters) and corresponding regional SITA raw thresholds were evaluated using linear regression for both (fixed corneal compensation and variable corneal compensation) SLP configurations. RESULTS No fixed corneal compensation SLP measurements were significantly associated with corresponding SITA visual field zone sensitivities after corrections for multiple comparisons. Seven variable corneal compensation RNFL parameters (superior, inferior, or mean RNFL thickness measurements) were significantly associated with their corresponding visual field zones with R2 values ranging from 0.13 (ellipse average) to 0.20 (superior average). CONCLUSION Variable corneal compensation to correct for subject-specific corneal polarization magnitude and corneal polarization axis improves the relationship between SLP-measured RNFL thickness and visual function measured by SITA perimetry.
منابع مشابه
Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
PURPOSE To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. METHODS Fifty-three eyes with an atypical birefri...
متن کاملGlaucoma detection using scanning laser polarimetry with variable corneal polarization compensation.
OBJECTIVE To compare the ability of scanning laser polarimetry (SLP) to discriminate between healthy and glaucomatous eyes with manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude (CPM) and corneal polarization axis (CPA) values. METHODS An SLP was modified to enable the measurement of CPM and CPA values so that compensation for corneal birefringence could ...
متن کاملScanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes.
PURPOSE To evaluate the relationship between visual function and retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry with variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). DESIGN Cross-sectional analysis of normal and glaucomatous eyes in a tertiary care academic referral practice. METHODS A commercial GDx nerve fiber analyzer...
متن کاملFourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.
PURPOSE To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurement...
متن کاملAssessment of the retinal nerve fiber layer of the normal and glaucomatous monkey with scanning laser polarimetry.
PURPOSE To describe and test a method for assessment of the monkey retinal nerve fiber layer (RNFL) with scanning laser polarimetry. METHODS A scanning laser polarimeter was modified to accommodate a variable corneal polarization compensator. Corneal polarization magnitude (CPM) and corneal polarization axis (CPA) of the anterior segment birefringence of normal and glaucomatous cynomolgus mon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 121 7 شماره
صفحات -
تاریخ انتشار 2003