Embedding embryos for high-resolution episcopic microscopy (HREM).
نویسندگان
چکیده
Episcopic fluorescence image capturing (EFIC) and high-resolution episcopic microscopy (HREM) are related techniques that are used to generate digital volume data and create three-dimensional (3D) images. Both techniques require specimens that are embedded in an appropriate medium, and images are captured from successive sections before removal from the embedded tissue block. EFIC detects autofluorescence emitted from the embedded tissue, whereas HREM requires the tissue to be stained with a fluorescent dye such as eosin. Different procedures are therefore necessary for embedding tissue for EFIC or HREM imaging. For HREM, the choice of fixative appears to be of little consequence. If gene expression patterns are to be visualized in addition to tissue architecture, whole-mount staining for gene expression patterns using the 4-nitro blue tetrazolium chloride (NBT)/5-bromo-4-chloro-3-indolyl phosphate (BCIP) or LacZ detection system must be performed before embedding of samples. This protocol describes the procedure for embedding E11.5 mouse embryos for HREM imaging. Processing times should be adapted for the size and nature of other specimens.
منابع مشابه
Generation of volume data by episcopic three-dimensional imaging of embryos.
Episcopic fluorescence image capturing (EFIC) and high-resolution episcopic microscopy (HREM) are related techniques that are used to generate digital volume data and create three-dimensional (3D) images. Both techniques require specimens that are embedded in an appropriate medium, and images are captured from successive sections before removal from the embedded tissue block. EFIC detects autof...
متن کاملEpiscopic three-dimensional imaging of embryos.
Episcopic fluorescence image capturing (EFIC) and high-resolution episcopic microscopy (HREM) are related techniques that are used to generate digital volume data and create three-dimensional (3D) images. Both techniques require specimens that are embedded in an appropriate medium, and images are captured from successive sections before removal from the embedded tissue block. EFIC detects autof...
متن کاملPhenotyping structural abnormalities in mouse embryos using high-resolution episcopic microscopy
The arrival of simple and reliable methods for 3D imaging of mouse embryos has opened the possibility of analysing normal and abnormal development in a far more systematic and comprehensive manner than has hitherto been possible. This will not only help to extend our understanding of normal tissue and organ development but, by applying the same approach to embryos from genetically modified mous...
متن کاملHigh-resolution Episcopic Microscopy (HREM) - Simple and Robust Protocols for Processing and Visualizing Organic Materials
We provide simple protocols for generating digital volume data with the high-resolution episcopic microscopy (HREM) method. HREM is capable of imaging organic materials with volumes up to 5 x 5 x 7 mm3 in typical numeric resolutions between 1 x 1 x 1 and 5 x 5 x 5 µm3. Specimens are embedded in methacrylate resin and sectioned on a microtome. After each section an image of the block surface is ...
متن کاملHREM: High-Resolution Episcopic Microscopy
The resin blocks are mounted on a motorized microtome. The microtome has to be modified to allow the block holder to reproducibly come to rest at a "photoposition" after each cut. E.g., the apparatus we operate in Vienna has its photoposition at the upper stopping point of the block holder excursion of a rotary microtome (Microtec CUT 4060E, microTec Laborgeräte GmbH). It is reproducibly reache...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cold Spring Harbor protocols
دوره 2012 6 شماره
صفحات -
تاریخ انتشار 2012