Comparison of thromboelastography to bleeding time and standard coagulation tests in patients after cardiopulmonary bypass.

نویسندگان

  • J H Essell
  • T J Martin
  • J Salinas
  • J M Thompson
  • V C Smith
چکیده

This prospective study of 36 adult patients undergoing cardiopulmonary bypass (CPB) was conducted to determine the utility of thromboelastography (TEG) versus platelet studies (bleeding time, platelet count, mean platelet volume) and standard coagulation tests (prothrombin time, activated partial thromboplastin time, fibrinogen) to more effectively discriminate patients likely to benefit from platelet or fresh frozen plasma (FFP) transfusion. Although the sensitivities of the bleeding time (71.4%) and platelet count (100%) were similar to the TEG (71.4%), the specificity (89.3%) of the TEG was greater than that of the bleeding time (78.5%) and platelet count (53.6%). Seven patients experienced clinically significant hemorrhage; 5 (71.4%) had an abnormal TEG. Three of 8 (38%) other patients with an abnormal TEG had no abnormal bleeding. Only 2 of 27 (7.4%) patients with a normal TEG had abnormal bleeding requiring platelet or FFP transfusion. Therefore, it is suggested that post-CPB patients with a normal TEG should not receive platelet or FFP transfusions empirically. If excessive bleeding is noted in a patient with a normal TEG, this suggests a surgically correctable etiology. Data from this series suggest that patients displaying an abnormal TEG appear to be at increased risk for hemorrhage; therefore, appropriate blood product support should be initiated at the first sign of accelerated bleeding.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries

Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...

متن کامل

The effects of cardiopulmonary bypass with hollow fiber membrane oxygenator on blood clotting measured by thromboelastography.

In cardiac surgical patients we investigated the effects of cardiopulmonary bypass (CPB) with a hollow fiber membrane oxygenator on blood clotting measured by thromboelastography (TEG). We found only a minimal change in the strength of blood clot described either by the TEG parameter MA (maximum amplitude) or by the shear modulus G calculated from MA. After CPB there was also a significant tend...

متن کامل

The effects of protamine overdose on coagulation parameters as measured by the thrombelastograph.

BACKGROUND AND OBJECTIVE Protamine is routinely administered following cardiopulmonary bypass in order to neutralize the effects of heparin. An excess of protamine can contribute to coagulopathy, hence predisposing to bleeding with associated morbidity and mortality. Thromboelastography (TEG) is recognized as an invaluable bedside tool to detect coagulation parameters; however, the effects of p...

متن کامل

How do we manage cardiopulmonary bypass coagulopathy?

BACKGROUND Patients who undergo cardiopulmonary bypass (CPB) are at risk for coagulopathy. Suboptimal turnaround time (TAT) of laboratory coagulation testing results in empiric administration of blood products to treat massive bleeding. We describe our initiative in establishing the coagulation-based hemotherapy (CBH) service, a clinical pathology consultation service that uses rapid TAT coagul...

متن کامل

Coagulopathies in Cyanotic Cardiac Patients: An Analysis with Three Point-of-care Testing Devices (Thromboelastography, Rotational Thromboelastometry, and Sonoclot Analyzer)

INTRODUCTION In the last few years, viscoelastic point-of-care (POC) coagulation devices such as thromboelastography (TEG), rotational thromboelastometry (ROTEM), and Sonoclot (SON) analyzer have been increasingly used in major surgeries for timely assessment and management of coagulopathies. The aim of the present study was to evaluate coagulation profile of cyanotic cardiac patients with TEG,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiothoracic and vascular anesthesia

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 1993