Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland.
نویسندگان
چکیده
This work aims at establishing a set of diagnostic reference levels (DRLs) for various types of examinations performed in diagnostic and interventional radiology. The average doses for 257 types of radiological examinations were established during the 1998 nationwide survey on the exposure of the Swiss population by radiodiagnostics. They were calculated using appropriate dosimetric models and average technical parameters. The DRLs were derived from the average doses using a multiplying factor of 1.5. The DRLs obtained were rounded and compared to the data reported in the literature. The results are in most cases comparable to the DRLs determined by the 3rd-quartile method. These discrepancies registered in some cases, particularly for complex examinations, can be explained by significant differences in the protocols and/or the technical parameters used. A set of DRLs is proposed for a large number of examinations to be used in Switzerland as temporary values until a national dosimetric database is set up.
منابع مشابه
Diagnostic reference levels at intraoral and dental panoramic examinations
Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraor...
متن کاملDiagnostic Reference Levels : the Swiss situation
The aim of this work is to describe how diagnostic reference levels (DRLs) are being established and implemented in Switzerland. Several nationwide surveys are launched in order to determine the patient dose distributions for a number of CT and fluoroscopy examinations that will be used to set up the corresponding DRLs. Meanwile the european recommended DRLs are considered. When no European rec...
متن کاملDiagnostic and Interventional Radiology: a Stradegy for Introducing Diagnistic Reference Levels Taking into Account the National Practice
Diagnostic reference levels (DRLs) are difficult to define in the case of X-ray examinations involving fluoroscopy particularly those performed in angiography and interventional radiology due to the large variability between examinations: fluoroscopy duration, number of images, image quality required. In order to tackle this problem a nation-wide dosimetric survey was performed in Switzerland i...
متن کاملLocal Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran
Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...
متن کاملLocal Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 111 3 شماره
صفحات -
تاریخ انتشار 2004