Use of locking compression plates for deformity correction of the forearm bones in children.

نویسندگان

  • Jiri Jochymek
  • Jan Skvaril
  • David Stary
  • Petr Gal
  • Ladislav Planka
چکیده

THE AIM OF THE STUDY The aim of our study was to assess treatment results of angular deformities in distal radius by a system of the locking compression plates (LCP) at our clinic. METHODS Our source data was collected prospectively from the records of patients where the locking compression plate was used for angulation correction of distal forearm between 2006 and 2007. The patients were divided by sex, the age range was defined and two groups were formed based on the initial diagnosis: the group of posttraumatic deformities (2 patients; 29 %) and the group of no traumatic deformities (3 patients with congenital shortening of ulna, valgus deformity and overgrowth of radius and 2 patients with exostoses multiplices with shortening of ulna and overgrowth of radius with ulnar angulation). The following parameters were set: radial articular angle and carpal slip prior to and after angulation correction, the healing period, the range of movement of the surrounding joints and occurrence of complications. RESULTS We recorded only one case of delayed healing which was subsequently sustained by autospongioplastics and adjusted to normal. In the rest of the cases deformity correction occurred and the defined parameters were then corrected to normal. We observed no postoperative complications or permanent consequences. CONCLUSIONS A two-year follow-up period monitoring treatment and therapeutic results of deformities in the forearm bones at our clinic, confirmed a minimal incidence of complications and a high percentage of successfully treated cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plastic deformity of forearm bones in skeletally mature patients (case repor)

Introduction: Plastic deformation of long bones can occur at any age, but is several times more common in children than in adults. This situation in adults is so rare that even a single case can be reported. The cause of the lower incidence in adults is the larger mineral content of adult bones relative to water with smaller haversian canals in comparison to children. Case report: Here we rep...

متن کامل

A case report of plastic deformity of fibula and fracture of tibia

Background: Plastic deformity is a fixed deformity of bones after application of force which is in contrast to elastic deformity, so it remains unchanged. It is a rare condition and is seen more commonly in upper extremity (forearm). Inability to recognize it causes limitation of motion and remaining of angular deformity. It occurs more commonly in children because of flexibility of their bones...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Modified Boyd’s Dual Onlay Bone Graft Technique for 15 Years Old Neglected Nonunion Fracture both Bone Forearm with Severe Angular Deformity: Case Report

INTRODUCTION Neglected case of nonunion of fracture both bones forearm with deformity is very difficult to manage. Treatment options are minimal. Identifying such a case in literature is also very rare. One such rare case is discussed here. CASE REPORT Here, we present a case of a 65-year-old male patient, who was operated 15 years back for fracture both bones forearm, with 3.5 mm dynamic com...

متن کامل

Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia

دوره 153 1  شماره 

صفحات  -

تاریخ انتشار 2009