The Effect of Misregistration Between CT-Attenuation and PET-Emission Images in 13N-Ammonia Myocardial PET/CT.

نویسندگان

  • Yoya Tomita
  • Masaki Ishida
  • Yasutaka Ichikawa
  • Naohisa Suzawa
  • Shigeki Kobayashi
  • Hisato Maeda
  • Kan Takeda
  • Hajime Sakuma
چکیده

UNLABELLED In 2-dimensional cardiac PET/CT, misregistration between the PET and CT images due to respiratory and cardiac motion causes tracer uptake to appear substantially reduced. The resolution and quality of the images have been considerably improved by the use of 3-dimensional (3D) PET acquisitions. In the current study, we investigated the impact that misregistration between PET and CT images has on myocardial (13)N-ammonia uptake in images reconstructed with 3D ordered-subset expectation maximization combined with time-of-flight and point-spread-function modeling. METHODS Eight healthy volunteers (7 men and 1 woman; mean age ± SD, 53 ± 19 y) underwent (13)N-ammonia cardiac PET/CT at rest. First, any misregistration between the PET and CT images was manually corrected to generate reference images. Then, the images were intentionally misregistered by shifting the PET images from the reference images by a degree of 1, 2, 3, 4, 5, 10, and 15 mm along both the x-axis (left) and the z-axis (cranial). For each degree of misregistration, the PET images were reconstructed using the CT-attenuation images. The left ventricular short-axis PET/CT images were divided into 4 segments: anterior wall, inferior wall, lateral wall, and septum. The erroneous decrease in myocardial uptake in basal, mid, and apical slices was visually graded using a 4-point scale (0 = none, 1 = mild, 2 = moderate, and 3 = severe). Wall-to-septum uptake ratios were evaluated for the anterior, inferior, and lateral walls in the basal, mid, and apical slices. RESULTS A statistically significant reduction in myocardial (13)N-ammonia uptake in the anterior (P < 0.01) and lateral (P < 0.05) walls was observed when misregistration was 10 mm or more. The uptake ratios for the anterior, lateral, and inferior walls in the reference images were 1.00 ± 0.04, 0.96 ± 0.08, and 0.91 ± 0.03, respectively. The ratios for the anterior and lateral walls significantly decreased when misregistration exceeded 10 mm (anterior wall, 0.80 ± 0.06, P < 0.0001; lateral wall, 0.82 ± 0.07, P < 0.01), whereas the ratio for the inferior wall was relatively small at all 7 degrees of misregistration (0.86 ± 0.05 at 15-mm misregistration, P = 0.06). CONCLUSION In PET/CT images reconstructed with 3D ordered-subset expectation maximization combined with time-of-flight and point-spread-function modeling, we found a statistically significant artifactual reduction in tracer uptake in heart regions overlapping lung when misregistration between PET and CT exceeded 10 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections.

UNLABELLED Cardiac PET combined with CT is rapidly expanding despite artifactual defects and false-positive results due to misregistration of PET and CT attenuation correction data-the frequency, cause, and correction of which remain undetermined. METHODS Two hundred fifty-nine consecutive patients underwent diagnostic rest-dipyridamole myocardial perfusion PET/CT using (82)Rb, a 16-slice PET...

متن کامل

Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.

UNLABELLED CT-based attenuation correction is a widely used option in commercial PET/CT scanners. However, as a result of a nonsimultaneous acquisition and differences in temporal resolution between both modalities, a potential misregistration between the PET and CT, especially in the thorax and the upper abdomen, can be found. We observed a substantial number of apparent perfusion defects in s...

متن کامل

Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: quantitative validation.

UNLABELLED Cardiac PET/CT is optimized by cine CT with dedicated shift software for manual correction of attenuation-emission misregistration. Separate rest and stress CT scans incur greater radiation dose to patients than does standard helical PET/CT or "pure" PET using rotating rod attenuation sources. To reduce radiation dose, we tested quantitative accuracy of using a single poststress cine...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2016