Determination of carbon isotopic measurement conditions for ceramide in skin using gas chromatography-combustion-isotope ratio mass spectrometry.

نویسندگان

  • Hiroyuki Haraguchi
  • Keita Yamada
  • Rumiko Miyashita
  • Kazuhiko Aida
  • Masao Ohnishi
  • Alexis Gilbert
  • Naohiro Yoshida
چکیده

The ceramide (Cer) content of skin and glucosylceramide (GlcCer) intake affect skin moisture conditions, but their mutual relation in skin remains unclear. For clarification of that mutual relation, carbon stable isotopes ((12)C and (13)C) are useful as a tracer. However, carbon isotopic measurement has not been applied to the study of clarifying their skin moisturizing effects. Therefore, we used gas chromatography / combustion / isotope ratio mass spectrometry (GC-C-IRMS) to ascertain the appropriate conditions for carbon isotopic measurements using synthesized Cer (SCer) in substitution for very low concentrations of Cer in skin. SCer was derivatized to trimethylsilylated SCer (TMS-SCer) quantitatively using N-trimethylsilylimidazole (TMSI) depending on the amount of SCer. The derivatization rates were 75-85%. Excess TMSI was removed using three cycles of hexane-water distribution. Under these conditions, carbon isotopic measurements of TMS-SCer conducted using GC-C-IRMS showed high repeatability and good inter-day variation (S.D. < 0.3‰). The carbon stable isotope ratio value (δ(13)C) of SCer calculated using a mass balance equation was compared with δ(13)C of underivatized SCer, which was regarded as the actual δ(13)C of SCer obtained using sealed tube combustion method. The difference between the calculated δ(13)C of SCer and δ(13)C of the underivatized SCer depended on the TMSI reagent supplier and on the number of hydroxyl groups to be derivatized in SCer. For accurate δ(13)C of Cer in skin using GC-C-IRMS, the measured δ(13)C of a target TMS-Cer must be calculated using a correction factor representing the difference in δ(13)C of underivatized standard SCer from that of TMS-standard SCer having a structure resembling that of the target Cer in skin. In addition, we show that the same lot of TMSI reagent from a specific supplier must be used throughout the experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gas chromatography/combustion/isotope ratio mass spectrometric analysis of the stable carbon composition of tetrols.

The stable carbon isotope compositions of tetrols, erythritol and threitol were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Using four tetrols with various delta(13)C values derivatized by methylboronic acid, the carbon isotope analysis method achieved excellent reproducibility and high accuracy. There was no carbon isotopic fractionation during the ...

متن کامل

Stable carbon isotope analyses of nanogram quantities of particulate organic carbon (pollen) with laser ablation nano combustion gas chromatography/isotope ratio mass spectrometry

RATIONALE Analyses of stable carbon isotope ratios (δ13 C values) of organic and inorganic matter remains have been instrumental for much of our understanding of present and past environmental and biological processes. Until recently, the analytical window of such analyses has been limited to samples containing at least several μg of carbon. METHODS Here we present a setup combining laser abl...

متن کامل

Isotopic ((13)C) analysis of dissolved organic carbon in stream water using an elemental analyzer coupled to a stable isotope ratio mass spectrometer.

A technique for measurement of the stable isotope composition of dissolved organic carbon (DOC) in stream water, using an elemental analyzer (EA) coupled to an isotope ratio mass spectrometer (IRMS), is described. Stream water samples were concentrated by rotary evaporation, acidified to remove dissolved inorganic carbon (DIC), and dried in silver cups prior to analysis. Precision was evaluated...

متن کامل

High precision isotope ratio monitoring techniques in mass spectrometry.

Isotope ratio monitoring following on-line combustion is a new method in gas chromatography/mass spectrometry (GC/MS) that allows the ratios of abundances of stable isotopes of elements such as carbon and nitrogen to be determined for individual compounds introduced via a gas chromatograph. It is the first combustion method that allows direct measurement of isotope ratios of individual molecula...

متن کامل

Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oleo science

دوره 63 12  شماره 

صفحات  -

تاریخ انتشار 2014