Dynamic Time to Surge Computation for Electric Driven Gas Compressors During Voltage Dips
نویسندگان
چکیده
This paper investigates the influence of voltage dips on large electric driven gas compressors (EDC) considering a typical application in the oil and gas industry. Voltage or power dips are electric disturbances encountered in EDC which are mainly caused by faults in the electrical grid and might last for durations up to 150ms. For gas compression applications, the loss of driver torque often puts the gas compression process at risk of surge conditions, which is a safety critical constraint. The critical nature of the present problem and the fast dynamics involved, pose challenging requirements for the control and safety systems of the gas compressor and the variable-speed drive system. The main focus of the present paper is the dynamic computation of the time to surge using online information of the estimated motor torque and a process model to predict the future behavior of the compression system. The time to surge can then be used for ride-through or shut-down decisions of the complete system, as well as for manipulating safety valves, e.g. the anti-surge valve. The fulfillment of strict real-time requirements and their direct implications on the complexity of the chosen prediction model and the implementation of the algorithm on an embedded system are also addressed in this article. As an industrial case study, the algorithm is applied to a voltage dip situation using high fidelity simulation data of a compression station.
منابع مشابه
Analysis of Grading Ring Design Parameters and Heat Sink Numbers Effect on Voltage Distribution and Leakage Current in Metal Oxide Surge Arrester
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester order to uniform the electric field distribution. One of the problems of arresters is leakage current in power frequency that different paramet...
متن کاملREGULAR PAPER Improvement of Surge Protection by Using an AlGaN/GaN-Based Metal–Semiconductor–Metal Two-Dimensional Electron Gas Varactor
In this paper, a varactor with metal–semiconductor–metal diodes on top of the (NH 4) 2 S/P 2 S 5-treated AlGaN/GaN two-dimensional electron gas epitaxial structure (MSM-2DEG) is proposed to the surge protection for the first time. The sulfur-treated MSM-2DEG varactor properties, including current–voltage (I–V), capacitance–voltage (C–V), and frequency response of the proposed surge protection c...
متن کاملModel Predictive Anti-Surge Control of Centrifugal Compressors with Variable-Speed Drives
In this article torque assisted anti-surge control (TASC), a compressor anti-surge control system based on model predictive control (MPC) is presented. TASC is implemented on an embedded system for the control of compressor stations with electrical variable-speed drives (VSD) which are used in applications such as natural gas transportation via pipelines. The manipulated variables of the propos...
متن کاملSite Performance Test Evaluation for Gas Turbine and Electric Motor Driven Compressors
Field testing of compressor packages driven by gas turbines or electric motors requires the accurate determination of efficiency, flow, head, and power in sometimes less than ideal working environments. This paper discusses field performance testing of centrifugal compressors and measurement uncertainties one can expect when following appropriate test guidelines. The primary focus is on compres...
متن کاملتحلیل و بهبود قابلیت ایستادگی توربین بادی با ژنراتور القایی دو سو تغذیه در برابر افتادگی نامتقارن ولتاژ
DFIG based wind turbines (WTs) are very sensitive to grid voltage dips. This is because the grid voltage dips imposed at the connection point of the DFIG to the grid induce large voltages in the rotor windings, resulting in high rotor current. According to high penetration of DFIG based WTs, it is important that the WTs remain connected to the grid during the voltage dips and improve the grid s...
متن کامل