Three procedures have been compared for monitoring heparin in patients undergoing cardiopulmonary bypass: (1) activated clotting time (ACT) (2) protamine titration, and (3) fluorometric substrate assay. The ACT monitors the degree of anticoagulation. It is easy to perform and is relatively inexpensive, however, it does not correlate well with heparin levels and may not accurately predict the protamine dose for neutralization of heparin at the completion of bypass. A protamine titration assay or an assay using a thrombin-sensitive fluorometric substrate measures the heparin level and calculates the protamine requirement at the completion of surgery; however, these assays do not indicate the degree of anticoagulation. The fluorometric assay is the less expensive of the two assay measuring heparin, but it requires an experienced technologist to perform the test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Heparin and Protamine Therapy during Cardiopulmonary Bypass by Activated Clotting time

Cardiopulmonary bypass depends on our ability to control the coagulation system. Heparin and protamine have been used for this purpose since the introduction of cardiopulmonary bypass. Although heparin has been used as an anticoagulant since 1935 there are still some unsolved questions as regarding its structure and metabolism. 1•2 Many principles have been proposed for total heparinization, mo...

متن کامل

Lepirudin as an alternative to "heparin allergy" during cardiopulmonary bypass

A treatment strategy of a difficult and unusual problem is presented. We are reporting a case of a patient who had a documented allergy to heparin and required Cardiac surgery for an ASD closure. The anticoagulation regime used during cardiopulmonary bypass was lepirudin based. This report indicates that r-hirudin provides effective anticoagulation, however unless ECT is monitoring, post operat...

متن کامل

Management of anticoagulation during cardiopulmonary bypass in a patient with allergy to heparin and heparin-like compounds: a case-report.

Hypersensitivity to heparin and heparin-like compounds is a rare condition that represents therapeutic challenges for patients requiring a cardiopulmonary bypass (CPB). We here report the case of a woman with a combined allergy to heparins (fractionated and unfractionated), danaparoid and fondaparinux. She underwent a mitral valve replacement under CBP using lepirudin for systemic anticoagulati...

متن کامل

Heparin Management: A Comparison

The following study deals with the inherent problem in determining a suitable protocol for monitoring heparin therapy for patients undergoing cardiopulmonary bypass surgery. 1•2•3.4 To assist perfusionists in the clinical setting of the operating room, two automated devices have been engineered to help monitor a safe heparinization level during cardiopulmonary bypass procedures. The two vehicle...

متن کامل

Use of ecarin clotting time (ECT) with lepirudin therapy in heparin-induced thrombocytopenia and cardiopulmonary bypass.

Heparin-induced thrombocytopenia (HIT) is described as an allergy-like adverse reaction to heparin. It is a potentially severe complication of heparin therapy that can result in serious or life-threatening venous or arterial thromboembolic events. In the United States, lepirudin (Aventis Pharma AG, Strasbourg, France) is an approved therapy for anticoagulation in patients with HIT requiring ant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 1984