Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Blinded, Randomized Controlled Trial With 5-Year Follow-up.

نویسندگان

  • Yuval Arama
  • Lucy J Salmon
  • Kesavan Sri-Ram
  • James Linklater
  • Justin P Roe
  • Leo A Pinczewski
چکیده

BACKGROUND Longer-term results of bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been reported, but results are specific to the exact screw material and design. Titanium and poly-L-lactic acid with hydroxyapatite (PLLA-HA) screw outcomes have been compared only to 2 years. PURPOSE/HYPOTHESIS The purpose of this study was to compare the clinical and radiologic outcomes of the PLLA-HA screw versus titanium screw for hamstring tendon ACLR over a 5-year follow-up period. The hypothesis was that there are no differences in clinical scores or tunnel widening between the PLLA-HA and the titanium screws and that the PLLA-HA screw as seen on magnetic resonance imaging (MRI) should show high-grade resorption and ossification response over 5 years. STUDY DESIGN Randomized controlled trial; Level of evidence, 1. METHODS A total of 40 patients undergoing ACLR were randomized to receive either a PLLA-HA screw (PLLA-HA group) or a titanium screw (titanium group) for ACL fixation. Blinded evaluation was performed at 2 and 5 years with the International Knee Documentation Committee and Lysholm knee score, KT-1000 arthrometer, single-legged hop test, and MRI to evaluate tunnel and screw volumes, periscrew ossification, graft integration, and cyst formation. RESULTS There was no difference in any clinical outcome measure at 2- or 5-year follow-up between the 2 groups. At 2 years, the femoral tunnel in the PLLA-HA group was smaller than that in the titanium group (P = .02); at 5 years, there was no difference. At 2 years, the femoral PLLA-HA screw was a mean 76% of its original volume, and by 5 years, it was 36%. At 2 years, the tibial PLLA-HA screw mean volume was 68% of its original volume, and by 5 years, it was 46%. At 5 years in the PLLA-HA group, 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the PLLA-HA group and no screw breakages. CONCLUSION There were equivalent clinical results between the PLLA-HA and titanium groups at 2- and 5-year follow-ups. The PLLA-HA screw was not associated with increased tunnel widening or cyst formation when compared with the titanium screw. The PLLA-HA screw demonstrated progressive screw resorption and gradual but incomplete ossification over 5 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of graft tissue on anterior cruciate ligament outcomes: a multicenter, prospective, randomized controlled trial comparing autograft hamstrings with fresh-frozen anterior tibialis allograft.

PURPOSE To compare the results and outcome of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring tendon versus fresh-frozen allograft anterior tibialis tendon. METHODS A prospective randomized study was conducted from September 2002 to October 2006. We randomized 147 patients to undergo ACL reconstruction with either autogenous hamstring or fresh-frozen allograft anter...

متن کامل

Arthroscopic reconstruction of the anterior cruciate ligament. A comparison of patellar tendon autograft and four-strand hamstring tendon autograft.

We compared the outcome of anterior cruciate ligament reconstruction using hamstring tendon autograft with outcome using patellar tendon autograft at 2 years after surgery. Patients had an isolated anterior cruciate ligament injury and, apart from the grafts, the arthroscopic surgical technique was identical. Prospective assessment was performed on 90 patients with isolated anterior cruciate li...

متن کامل

A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.

INTRODUCTION Anterior Cruciate Ligament (ACL) is as one of the most frequently injured ligaments in the modern contact sports scenario. Graft fixations can be achieved during anterior cruciate ligament (ACL) reconstructions by using either bioabsorbable screws or metal screws. The objective of this study was to compare the functional outcomes after bioabsorbable and metallic interference screw ...

متن کامل

A prospective randomized comparison of patellar tendon versus semitendinosus and gracilis tendon autografts for anterior cruciate ligament reconstruction.

Seventy patients with patellar tendon or hamstring tendon autografts for single-incision anterior cruciate ligament reconstruction were evaluated at least 2 years after surgery. All reconstructions were performed by the same surgeon, and metal interference screws were used for fixation of all grafts. No significant differences were noted between groups for Lysholm score, reduction in activity, ...

متن کامل

Reconstruction of the anterior cruciate ligament:a comparison between bone-patellar tendon-bone grafts and four-strand hamstring grafts

  Background :Disruption of anterior cruciate ligament (ACL) is a common ligamentous injury of the knee. The choice of graft for (ACL) reconstruction remains controversial. This prospective, randomized clinical trial aimed to compare clinical results of bone-patellar tendon-bone (BPTB) grafts and four-strand semitendinosus-gracilis (ST) grafts for ACL reconstruction over a 3-year follow-up inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 43 8  شماره 

صفحات  -

تاریخ انتشار 2015