Correction of gradient-induced phase errors in radial MRI.

نویسندگان

  • Amir Moussavi
  • Markus Untenberger
  • Martin Uecker
  • Jens Frahm
چکیده

PURPOSE To correct gradient-induced phase errors in radial MRI. METHODS Gradient-induced eddy currents affect the MRI data acquisition by gradient delays and phase errors that may lead to severe image artifacts for non-Cartesian imaging scenarios such as radial trajectories. While gradient delays are dealt with by respective shifts of the acquisition window during radial image acquisition, this work introduces a simple method for quantifying and correcting phase errors from the actual data prior to image reconstruction. For a given gradient system, the approach yields a specific phase error per gradient that can be used for correcting the raw data. RESULTS Phantom studies at 9.4 T demonstrated marked improvements in radial image quality. It could be shown that the phase correction is not compromised by data undersampling. Moreover, the selective correction of gradient-induced phase errors retained the phase information caused by different concentrations of a paramagnetic contrast agent. CONCLUSION The proposed method does not require additional reference measurements and separately corrects for phase errors induced by eddy currents, while retaining the residual phase of the object which may carry physiologic information.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in real-time phase-contrast flow MRI using asymmetric radial gradient echoes.

PURPOSE To provide multidimensional velocity compensation for real-time phase-contrast flow MRI. METHODS The proposed method introduces asymmetric gradient echoes for highly undersampled radial FLASH MRI with phase-sensitive image reconstruction by regularized nonlinear inversion (NLINV). Using an adapted gradient delay correction the resulting image quality was analyzed by simulations and ex...

متن کامل

Analysis and Correction of the Effect of Spatial Gradient Field Distortions on Velocity Measurements with Phase Contrast MRI

An analysis of the effect of spatially inhomogeneous gradient fields on quantitative phase contrast MRI measurements is presented. A local error in the gradient strength leads to incorrect velocity encoding. Here the error in the measured velocities is compared to a theoretical model of gradient field imperfection. Depending on the spatial location of the region of interest for velocity measure...

متن کامل

Effects of myopic spectacle correction and radial refractive gradient spectacles on peripheral refraction

The recent observation that central refractive development might be controlled by the refractive errors in the periphery, also in primates, revived the interest in the peripheral optics of the eye. We optimized an eccentric photorefractor to measure the peripheral refractive error in the vertical pupil meridian over the horizontal visual field (from -45 degrees to 45 degrees ), with and without...

متن کامل

Real-time correction of rigid body motion-induced phase errors for diffusion-weighted steady-state free precession imaging.

PURPOSE Diffusion contrast in diffusion-weighted steady-state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion-induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three-dimensional (3D) navigator-based real-time correction of t...

متن کامل

Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI

PURPOSE To evaluate convex gradient optimization (CVX) for increased spatiotemporal resolution and improved accuracy for phase-contrast MRI (PC-MRI). METHODS A conventional flow-compensated and flow-encoded (FCFE) PC-MRI sequence was compared with a CVX PC-MRI sequence using numerical simulations, flow phantom experiments, and in vivo experiments. Flow measurements within the ascending aorta,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 2014