Axonal stimulation for end-plate jitter studies.
نویسندگان
چکیده
This single fibre EMG study compares the standard method of neuromuscular jitter measurement in voluntarily activated muscle to that by intramuscular electrical stimulation of motor axons in a group of normal subjects. The latter method avoids the interdischarge interval-dependent jitter, as well as a possible failure to recognise split muscle fibres. The mean MCD on axonal stimulation was only 5.2 microseconds less than in the voluntary activation study and was thus 8% more than theoretically expected for single motor end plates. The difference could be due to an axonal jitter and some other factors. Axonal stimulation has proved to be a relatively easy and reliable method for routine estimation of neuromuscular jitter, provided that the resolution of time measurement is better than 2 microseconds, so that low jitter due to occasional direct muscle fibre stimulation is not mistaken for a normal reading. The upper normal limits for the extensor digitorum communis muscle suggested by the present study are 40 microseconds (individual muscle fibres) and 25 microseconds (mean of 30 muscle fibres).
منابع مشابه
onset Alzheimer ' s disease in Argentina . Apolipoprotein E polymorphism and late
seem to be the origin of spontaneous activities in our patient. Pharmacological studies support this hypothesis. Stimulation SFEMG confirmed a normal neuromuscular transmission in Schwartz-Jampel syndrome, whereas voluntary SFEMG was not helpful due to technical difficulties. Jitter studies have been performed in three previous reports of Schwartz-Jampel syndrome.2 4 However, adequate numbers o...
متن کاملMotor amplitude of median nerve with stimulation in the palm a reliable indicator for axonal loss in carpal tunnel syndrome
Background and Aim: The present study aimed to use the median nerve compound muscle action potential (CMAP) amplitude by stimulation at the palm instead of abductor pollicis brevis (APB) needle electromyography (EMG) for determining a sign of axonal loss in patients with carpal tunnel syndrome (CTS). Methods and Materials/Patients: This study was performed on 180 patients with CTS referred to ...
متن کاملFacioscapulohumeral dystrophy: jitter in facial muscles.
Motor end plate jitter was studied by single fibre EMG in the orbicularis oculi muscle of eight patients with facioscapulohumeral dystrophy activated by extramuscular nerve stimulation. The jitter was found to be slightly larger in comparison with the normal controls, although still within the normal limits in each patient. The findings are considered to indicate absence of any significant neur...
متن کاملAge-Dependent Regeneration by Using Electromyographical Study Foliowing Sciatic Nerve Injury in Rat
Purpose: There are extensive evidences that show axonal processes of the nervous system (peripheral and/or central) may be degenerated after nerve injuries. Axonal regeneration is relation to various factors. In this investigation we decided to evaluate the effects of nerve regeneration age-dependent on injured rat sciatic nerv. Materials and Methods: For this study, the right sciatic nerve of...
متن کاملThe Parameters of Single Fibre Emg
THE PARAMETERS OF SINGLE FIBRE EMG To detect abnormal neuromuscular transmission, two parameters are analysed: ‘jitter’ as an indicator of irregularity of neuromuscular transmission, and ‘blocking’ as an indicator of failure of transmission (Stålberg and Trontelj 1994). Each lower motor neurone arising from an anterior horn of the spinal cord connects with a number of muscle fi bres via the ter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 49 6 شماره
صفحات -
تاریخ انتشار 1986