Evaluation of the Effects of Processing Delays and Protective Plastic Cases on Image Quality of a Photostimulable Phosphor Plate System

نویسندگان

  • Clóvis Monteiro Bramante
  • Alexandre Silva Bramante
  • Rogério Emílio de Souza
  • Ivaldo Gomes Moraes
  • Norberti Bernardineli
  • Roberto Brandão Garcia
چکیده

This ex vivo study evaluated the quality of digital radiographic images obtained with the photostimulable phosphor plate system (Digora) according to the processing delay and maintenance of optical plates in either opaque (supplied with the system) or transparent protective plastic cases during this period. Five radiographs were obtained from the mandibular molar region of a dry human mandible using optical plates. These plates were placed in the protective plastic cases before obtaining the radiographs and were processed immediately or after processing delays of 5, 60 and 120 min, when the case was removed. The results revealed a reduction in image quality when processing was delay 120 min compared to the other times. The opaque case provided better protection to the sensor than the transparent case. In conclusion, a 120-min processing delay for the Digora system caused a reduction in image quality, yet without interfering with the quality of diagnosis. The opaque case supplied by the system's manufacturer provided better protection to the optical plate than the transparent case.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل

Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...

متن کامل

Comparison of the Delay in Processing Time and Protective Plastic Cases in Two Phosphor Plate Systems

OBJECTIVE The purpose of this study was to analyze two phosphor plate systems (PSPs) (Dürr Dental, Digora Optime) according to their scanning delay and protective plastic case performances. METHODS Two PSPs using an aluminum step wedge were exposed. These plates were placed in three different protective plastic cases (manufacturers' original cases, black case, and white case) before obtaining...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Comparison of Different Imaging Techniques for the Evaluation of Proximity between Molars and the Mandibular Canal

Background and Aim: To compare the radiographic distance from the inferior part of mandibular second and third molars to the superior border of mandibular canal on radiographs obtained by conventional periapical radiographs, intraoral photostimulable phosphor plate (Intraoral PSP) and panoramic photostimulable phosphor plate (Panoramic PSP). Subjects and Methods: The study was carried out on 25...

متن کامل

مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندان‌های اندو شده (مطالعه آزمایشگاهی)

  Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.   Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2008