Direct determination of verapamil in rat plasma by coupled column microbore-HPLC method.
نویسندگان
چکیده
This report describes an automated coupled column microbore-high-performance liquid chromatography (HPLC) with fluorescence detection for direct determination of verapamil in small volume of rat plasma. We used HPLC system consisting of three columns such as precolumn, intermediate and analytical column and six-port switching valve and injected small volume of rat plasma to the system without sample preparation. An aliquot of sample was directly injected into Capcell Pak MF Ph precolumn for clean-up and enrichment, 35 mm Capcell Pak C18, intermediate column for concentration of compounds and 250 mm Capcell Pak C18 analytical column for separation of compounds and two mobile phases are used as mobile phase A (50mM ammonium phosphate, pH 4.5) and B (50mM ammonium phosphate:acetonitrile=70:30 v/v). Analysis of verapamil and internal standard, propranolol was performed with direct injection of 10 microl of rat plasma to the system and were eluted at 22 and 12 min, respectively, at a mobile phase flow rate of 0.5 (mobile phase A) and 0.15 ml/min (mobile phase B). The peaks of verapamil and internal standard were good shapes and well separated from any interfering endogenous peaks during a total run time of 25 min. The calibration curve for verapamil showed good linearity (r(2)=0.9997) over the concentration range of 0.01-2.50 microg/ml. The mean RSD (%) values of intra-day (n=5) and inter-day (n=5) variability of verapamil ranged from 1.96 to 9.06 and 0.62 to 3.08%, respectively. The LOD and LOQ were 0.01 and 0.025 microg/ml, respectively, for verapamil using 10 microl of rat plasma. An automated coupled column microbore-HPLC method was successfully applied to a pharmacokinetic study after intravenous injection of 3mg/kg of verapamil to the normal and dimethylnitrosamine (DMN)-induced hepatofibrotic rats.
منابع مشابه
High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملDetermination of Glycyrrhetic Acid in Rat Plasma by HPLC After Oral Administration of Licorice Aqueous Extract
Licorice is obtained from Glycyrrhiza glabra (G. glabra) in Iran. Glycyrrhizin is the main constituent of G. glabra and has several pharmacological effects. It is hydrolyzed to glycyrrhetic acid (GA) in the intestine after oral administration. In this study, a novel HPLC method was used to determine the concentration of GA in rat plasma after oral administration ...
متن کاملSelective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction
Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pharmaceutical and biomedical analysis
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2005