Contrast Free Duplex-Assisted EVAR in Patients with Chronic Renal Insufficiency.
نویسندگان
چکیده
Renal insufficiency and allergy for iodinated contrast are the main contra-indications for Endovascular Aortic Repair (EVAR). Various techniques have been used to minimize utilization of contrast in order to prevent contrast induced nephropathy. EVAR can be performed without nephrotoxic contrast, using additional duplex-guidance. This report describes three cases of duplex-assisted EVAR in patients with chronic renal insufficiency.
منابع مشابه
Safety and accuracy of endovascular aneurysm repair without pre-operative and intra-operative contrast agent.
BACKGROUND Severe chronic kidney disease is a major limitation for endovascular aortic aneurysm repair (EVAR). The aim of this study is to assess the safety and accuracy of fusion imaging, when performing EVAR in the absence of pre- and intra-operative contrast agents. METHODS From October 2013 to February 2014, every patient requiring EVAR and presenting with severe chronic renal impairment ...
متن کاملSagliker Syndrome in a Patient with Secondary Hyperparathyroidism and Chronic Renal Insufficiency: A Case Report
Sagliker syndrome is a rare form of renal osteodystrophy resulted from untreated secondary hyperparathyroidism. It is described by severe skeletal deformities, high level of PTH in patients with chronic renal failure, and deformed face. This paper reports a 44-year-old male patient with the mentioned characteristics. In addition to the unique clinical features, high levels of ALP and PTH hormon...
متن کاملCarbon dioxide digital subtraction angiography-assisted endovascular aortic aneurysm repair in the azotemic patient.
OBJECTIVE This report analyzes the safety and efficacy of carbon dioxide digital subtraction angiography (CO(2)-DSA) for EVAR in a group of patients with renal insufficiency compared with a concurrent group of patients with normal renal function undergoing EVAR with iodinated contrast angiography (ICA). METHODS Between 2003 and 2005, 100 consecutive patients who underwent EVAR using ICA, CO(2...
متن کاملEndovascular aortic aneurysm repair with carbon dioxide-guided angiography in patients with renal insufficiency.
OBJECTIVE Renal dysfunction following endovascular abdominal aortic aneurysm repair (EVAR) remains a significant source of morbidity and mortality. We studied the use of carbon dioxide (CO(2)) as a non-nephrotoxic contrast agent for EVAR. METHODS Recorded data from 114 consecutive patients who underwent EVAR with CO(2) as the contrast agent over 44 months were retrospectively analyzed. CO(2) ...
متن کاملEVAR Guided by 3D Image Fusion and CO2 DSA: A New Imaging Combination for Patients With Renal Insufficiency.
PURPOSE To present a new combination of imaging techniques that helps reduce the use of iodinated contrast during endovascular aneurysm repair (EVAR) procedures in patients with renal insufficiency. TECHNIQUE Relevant anatomical structures are marked in the preprocedure computed tomography (CT) angiogram. A 3D-3D image fusion between the preprocedure CT and an intraprocedure cone-beam CT is p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of vascular diseases
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2014