Protection of Critical Structures During Radiofrequency Ablation of Adjacent Myocardial Tissue Using Catheter Tips Partially Insulated With Thermally Conductive Material
نویسندگان
چکیده
METHODS Open-irrigated, 4and 8-mm RF ablation catheter tips were insulated partially by coating one-half of their surfaces with a layer of vinyl, silicone, vinyl–silicone, polyurethane, or a composite of aluminum oxide/boron nitride (AOBN). These coated catheters or corresponding noninsulated catheters were positioned with 10 g of force on viable bovine myocardial tissue during RF application in an ex vivo setup. Tip temperatures, power, and lesion volumes were compared. The most effective coating, AOBN, was modified further by adding fenestrations to aid in passive cooling. PIFA catheters with fenestrated AOBN coating were then tested in an in vivo porcine model to target myocardial tissue adjacent to the AV node and the phrenic nerve.
منابع مشابه
An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation
Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...
متن کاملImages in Electrophysiology: Multiple Effects of Radiofrequency Ablation
Radiofrequency (RF) catheter ablation is the preferred choice for the treatment of symptomatic reentrant arrhythmias associated with accessory pathways or dual atrioventricular conduction. The mechanism of irreversible tissue injury by the RF catheter ablation is primarily thermally mediated [1,2]. The myocardial cellular electrophysiological effects of hyperthermia muscle have been recently ou...
متن کاملEpicardial Catheter Ablation Using High-Intensity Ultrasound: Validation in a Swine Model.
BACKGROUND Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, ...
متن کاملPulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report
Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...
متن کاملShort-term results of substrate mapping and radiofrequency ablation of ischemic ventricular tachycardia using a saline-irrigated catheter.
OBJECTIVES We evaluated the safety and acute procedural efficacy of a combined electrophysiologic and anatomic approach to ablation of all inducible ventricular tachycardias (VT) during sinus rhythm using an irrigated radiofrequency (RF) ablation catheter. BACKGROUND Ventricular tachycardia associated with chronic myocardial infarction (MI) is frequently hemodynamically intolerable and associ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -