Diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies and appropriateness of performed hysteroscopies among asymptomatic postmenopausal women.

نویسندگان

  • L Giannella
  • K Mfuta
  • T Setti
  • F Boselli
  • E Bergamini
  • L B Cerami
چکیده

OBJECTIVE To measure the diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies among asymptomatic postmenopausal women, and to test the diagnostic accuracy and appropriateness of performed hysteroscopies. STUDY DESIGN Prospective study of 268 asymptomatic postmenopausal women with endometrial thickness ≥4 mm referred to diagnostic hysteroscopy. The diagnostic accuracy of various endometrial thickness cut-off values was tested. Histological and hysteroscopic results were compared to measure the diagnostic accuracy of outpatient hysteroscopies. RESULTS No endometrial thickness cut-off values had optimal diagnostic accuracy [positive likelihood ratio (LR+) >10 and negative likelihood ratio (LR-) <0.1]. The best endometrial thickness cut-off value for the detection of all intra-uterine pathologies was ≥8 mm (LR+ 10.05 and LR- 0.22). An endometrial thickness cut-off value ≥10 mm did not miss any cases of endometrial cancer. The success rate of diagnostic hysteroscopy was 89%, but 97% of these revealed a benign intra-uterine pathology. The diagnostic accuracy of hysteroscopy was optimal for all intra-uterine pathologies, except endometrial hyperplasia (LR- 0.52). CONCLUSION Using an endometrial thickness cut-off value ≥4 mm, only 3% of performed hysteroscopies were useful for the detection of pre-malignant or malignant lesions. Despite the finding that endometrial thickness did not show optimal diagnostic accuracy, using the best cut-off value (≥8 mm) may be helpful to decrease the number of false-positive results. No cases of endometrial cancer were diagnosed in asymptomatic postmenopausal women with endometrial thickness <10mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of transvaginal ultrasonography accuracy in the diagnosis of uterine pathologies in women with abnormal uterine bleeding

Abstract Background: The most common causes of abnormal uterine bleeding in women of reproductive age are uterine structural abnormalities. There are several modalities for the examination of abnormal uterine bleeding, including transvaginal ultrasound and hysteroscopy. In this study, we aimed to investigate the diagnostic accuracy of hysteroscopy versus transvaginal ultrasound in the diagnosis...

متن کامل

Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss

Objective: to compare diagnostic values of two dimensional trans-vaginal sonography (TVS) and office hysteroscopy (OH) for evaluation of endometrial pathologies in cases with repeated implantation failure (RIF) or recurrent pregnancy loss (RPL). Methods and Materials: This prospective study was performed in Royan institute from December 2013 to January 2015. TVS was performed before hysteroscop...

متن کامل

Hysteroscopy: A necessary method for detecting uterine pathologies in post-menopausal women with abnormal uterine bleeding or increased endometrial thickness

OBJECTIVE To investigate the histologic and hysteroscopic findings of post-menopausal women with uterine bleeding and asymptomatic women with increased endometrial thickness equal or more than 5 mm. MATERIALS AND METHODS This cross-sectional study was performed between May 2014 and June 2015 on 110 post-menopausal women aged 40-82 years. The women were divided into two groups: Women with abno...

متن کامل

Diagnostic accuracy of sonohysterography compared to endometrial biopsy in pre-menopausal women with abnormal uterine bleeding

  Background: AUB is a common cause of women’s referring to gynecologists. Although hysteroscopy is known as the gold standard technique for diagnosing the cause of AUB, sonohysterography is less invasive, and it is performed by general gynecologists. The purpose of this study was to evaluate the diagnostic performance of sonohysterography compared to the results of the endometrial biopsy, guid...

متن کامل

[Ultrasound detection of endometrial fluid in postmenopausal women].

UNLABELLED The aim, of this prospective study was to estimate whether the presence of endometrial fluid detected by transvaginal ultrasound investigation was a marker for the pathological changes of the endometrium in postmenopausal women. MATERIAL AND METHODS 128 postmenopausal women with uterine bleeding and 29 asymptomatic postmenopausal women underwent transvaginal ultrasound investigatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of obstetrics, gynecology, and reproductive biology

دوره 177  شماره 

صفحات  -

تاریخ انتشار 2014