Endoscope-Assisted and Controlled Argus II Epiretinal Prosthesis Implantation in Late-Stage Retinitis Pigmentosa: A Report of 2 Cases

نویسندگان

  • Emin Özmert
  • Sibel Demirel
چکیده

Several different approaches for restoring sight in subjects who are blind due to outer retinal degeneration are currently under investigation, including stem cell therapy, gene therapy, and visual prostheses. Although many different types of visual prostheses have shown promise, to date, the Argus II Epiretinal Prosthesis System, developed in a clinical setting over the course of 10 years, is the world's first and only retinal prosthesis that has been approved by the United States Food and Drug Administration (FDA) and has been given the CE-Mark for sale within the European Economic Area (EEA). The incidence of serious adverse events from Argus II implantation decreased over time after minor changes in the implant design and improvements in the surgical steps used for the procedure had been made. In order to further decrease the scleral incision-related complications and enhance the assessment of the tack position and the contact between the array and the inner macular surface, we used an ophthalmic endoscope during the regular course of Argus II implantation surgery in 2 patients with late-stage retinitis pigmentosa in an attempt to improve the anatomical and functional outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of Structural and Functional MRI Acquisition with Unpowered Implants in Argus II Retinal Prosthesis Patients: A Case Study.

PURPOSE Magnetic resonance imaging (MRI) can measure the effects of vision loss and recovery on brain function and structure. In this case study, we sought to determine the feasibility of acquiring anatomical and functional MRI data in recipients of the Argus II epiretinal prosthesis system. METHODS Following successful implantation with the Argus II device, two retinitis pigmentosa (RP) pati...

متن کامل

Use of the Argus II retinal prosthesis to improve visual guidance of fine hand movements.

PURPOSE We studied the capabilities of the Argus II retinal prosthesis for guiding fine hand movement, and demonstrated and quantified guidance improvement when using the device over when not using the device for progressively less predictable trajectories. METHODS A total of 21 patients with retinitis pigmentosa (RP), remaining vision no more than bare light perception, and an implanted Argu...

متن کامل

Improvements in vision‐related quality of life in blind patients implanted with the Argus II Epiretinal Prosthesis

BACKGROUND The purpose of this analysis is to report the change in quality of life (QoL) after treatment with the Argus II Epiretinal Prosthesis in patients with end-stage retinitis pigmentosa. METHODS The Vision and Quality of Life Index (VisQoL) was used to assess changes in QoL dimensions and overall utility score in a prospective 30-patient single-arm clinical study. VisQoL is a multi-att...

متن کامل

Clinical Trials Use of the Argus II Retinal Prosthesis to Improve Visual Guidance of Fine Hand Movements

METHODS. A total of 21 patients with retinitis pigmentosa (RP), remaining vision no more than bare light perception, and an implanted Argus II epiretinal prostheses used a touchscreen to trace white paths on black backgrounds. Sets of paths were divided into three categories: right-angle/single-turn, mixedangle/single-turn, and mixed-angle/two-turn. Subjects trained on paths by using prosthetic...

متن کامل

The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis.

OBJECTIVE To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. METHODS Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple ...