Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea
نویسندگان
چکیده
Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children.
منابع مشابه
Role of ICT malaria immunochromatographic test for rapid diagnosis of malaria.
OBJECTIVE To evaluate the sensitivity and specificity of immunochromatographic test (ICT) malaria p.f/p.v using microscopy as the gold standard diagnosis. METHODS Five hundred and sixty patients of both sexes and all age groups with clinical suspicion of malaria were studied. Venous blood was collected for microscopy and ICT. Thick and thin films prepared and stained with Leishman's stain wer...
متن کاملPrevalence of anemia and associated factors in children living in urban and rural settings from Bata District, Equatorial Guinea, 2013
Anemia in children under 5 years of age is a global public health problem. According to the World Health Organization the current rate of anemia among preschool aged children in Equatorial Guinea is 66%. No information is available above this age. The cross-sectional Prevamal Survey was conducted in 2013 aimed at providing baseline data on malaria prevalence in children aged 2 months-15 years o...
متن کاملField evaluation of the ICT malaria P.f/P.v immunochromatographic test for detection of Plasmodium falciparum and Plasmodium vivax in patients with a presumptive clinical diagnosis of malaria in eastern Indonesia.
In areas such as eastern Indonesia where both Plasmodium falciparum and Plasmodium vivax occur, rapid antigen detection tests for malaria need to be able to detect both species. We evaluated the new combined P. falciparum-P. vivax immunochromatographic test (ICT Malaria P.f/P.v.) in Radamata Primary Health Centre, Sumba, Indonesia, from February to May 1998 with 560 symptomatic adults and child...
متن کاملDiagnostic methods of malaria in Eastern Nepal: a comparative study of traditional and two rapid diagnostic tests.
This study compared the diagnostic accuracy of Quantitative Buffy Coat (QBC) a fluorescent microscopy test and OptiMAL, an immunochromatographic dip stick test against conventional microscopy for the detection of malaria at a tertiary teaching hospital situated in Eastern Nepal. 100 clinically suspected malaria patients with positive and negative parasitemia were assessed under conventional mic...
متن کاملComparison of Rapid Immunochromatographic Assays (ict Malaria P.f. /p.v. Test and Optimal Test) with Microscopy for Detection of Malaria Parasites
This study was conducted to compare the ability of developed immunochromatographic assays, ICT malaria P.f./P.v. test and OptiMAL test with standard microscopy for the diagnosis of malaria parasites. Blood samples were obtained from 150 patients clinically suspected of having malaria. A total of 59 samples (39.3%) were positive by blood films while 64 (42.7%) were positive by ICT p.f./p.v. and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2010 شماره
صفحات -
تاریخ انتشار 2010