Acoustic noise transfer function in clinical MRI a multicenter analysis.

نویسندگان

  • Takashi Hamaguchi
  • Tosiaki Miyati
  • Naoki Ohno
  • Masaya Hirano
  • Norio Hayashi
  • Toshifumi Gabata
  • Osamu Matsui
  • Tatsuhiko Matsushita
  • Tomoyuki Yamamoto
  • Yasuhiro Fujiwara
  • Hirohiko Kimura
  • Hiroyasu Takeda
  • Yasuo Takehara
چکیده

RATIONALE AND OBJECTIVES Acoustic noise both in terms of its magnitude and frequency during magnetic resonance imaging (MRI) scan is influenced by imaging parameters and pulse sequences. It varies because of many different factors such as structure, materials, and magnetic field strength. The purpose of our study is to evaluate the characteristics of acoustic noise independent of MRI scan protocol by measuring a gradient-pulse-to-acoustic-noise transfer function (GPAN-TF) at various MRI scanners. MATERIALS AND METHODS We measured sound pressure levels in the frequency domain in a 0.4-T, seven 1.5-T, and three 3.0-T clinical MRI systems when applying a simple narrower trapezoidal gradient pulse. We calculated a GPAN-TF [μPa/(mT/m)] in each gradient coil (ie, X, Y, and Z-axis) by the deconvolution process. RESULTS GPAN-TF at a high-frequency range (1000-10,000 Hz) was larger than that at low frequency for all MRI (P<0.01) scanners except for a low static field machine. For high frequency (>1000 Hz), the 3.0-T MRI scanner had a larger GPAN-TF than that of 0.4-T and 1.5-T (P < .01). MR scanner with a vacuum chamber reduced GPAN-TF at a lower frequency (P < .01), but this effect decreased at higher frequency. CONCLUSION GPAN-TF analysis makes it possible to obtain more detailed information on acoustic noise properties among MRI scanners.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise pollution analysis in Tehran cement plant

&nbsp; Background : Cement industry has many process units. Basically all of these units can be considered as a source of noise. Since noise pollution is defined based on its offensive hearing effects, the importance of the noise sources depends directly on the number of workers in the unit. &nbsp; Materials and Methods : An experimental study has been done at Tehran cement factory to recogn...

متن کامل

A Bayesian approach for image denoising in MRI

Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...

متن کامل

The Study of Vocal Function in Patients With Early Laryngeal Carcinoma After Transoral Laser Microsurgery

Objective Today transoral laser microsurgery is considered as one of the first options to control early laryngeal cancer, and voice disorder is one of the inevitable complications of this therapeutic component. This study aimed to compare the vocal function in patients with early-stage laryngeal cancer following laser surgery with healthy individuals with normal voice quality using acoustic ana...

متن کامل

Experimental Study of Active Acoustic Noise Control in a 4T MRI Scanner In-Situ

Introduction The acoustic noise generated from the MRI system is a serious safety concern as well as a technical challenge for MR and acoustic noise control scientists. The emitted high noise levels can be both annoying and harmful to patients and healthcare workers, especially after long term exposure. Although various passive methods have been proposed to deal with this problem, active noise ...

متن کامل

An Adaptive Hierarchical Method Based on Wavelet and Adaptive Filtering for MRI Denoising

MRI is one of the most powerful techniques to study the internal structure of the body. MRI image quality is affected by various noises. Noises in MRI are usually thermal and mainly due to the motion of charged particles in the coil. Noise in MRI images also cause a limitation in the study of visual images as well as computer analysis of the images. In this paper, first, it is proved that proba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Academic radiology

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2011