Design and beam transport simulations of a multistage collector for the Israeli EA-FEM

نویسندگان

  • M. Tecimer
  • M. Canter
  • S. Efimov
  • A. Gover
  • J. Sokolowski
چکیده

A four stage asymmetric type depressed collector has been designed for the Israeli mm-wave FEM that is driven by a 1.4MeV, 1.5A electron beam. After leaving the interaction section the spent beam has an energy spread of 120 keV and 75pmmmrad normalized beam emittance. Simulations of the beam transport system from the undulator exit through the decelerator tube into the collector have been carried out using EGUN and GPT codes. The latter has also been employed to study trajectories of the primary and scattered particles within the collector, optimizing the asymmetrical collector geometry and the electrode potentials at the presence of a deflecting magnetic field. The estimated overall system and collector efficiencies reach 50% and 70%, respectively, with a beam recovery of 99.6%. The design is aimed to attain millisecond long pulse operation and subsequently 1 kW average power. Simulation results are implemented in a mechanical design that leads to a simple, cost efficient assembly eliminating ceramic insulator rings between collector stages and the associated brazing in the manufacturing process. Instead, each copper plate is supported by insulating posts and freely displaceable within the vacuum chamber. We report on the simulation results of the beam transport and recovery systems and on the mechanical aspects of the multistage collector design. r 2001 Published by Elsevier Science B.V.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3d Design of the Fusion-fem Depressed Collector Using the General Particle Tracer (gpt) Code

The “Rijnhuizen” Fusion Free-Electron Maser (FEM) is the pilot experiment for a high power, mm-wave source, tunable in the range 130-260 GHz. The FEM has generated 730 kW output power during 10 μs pulses. To increase the overall efficiency to over 50 % and to reach a pulse length of at least 100 ms, an electron beam charge and energy recovery system is currently being designed and installed. Th...

متن کامل

Beam & Shell Models for Composite Straight or Curved Bridge Decks with Intermediate Diaphragms & Assessment of Design Specifications

In this research effort, the generalized warping and distortional problem of straight or horizontally curved composite beams of arbitrary cross section, loading and boundary conditions is presented. An inclined plane of curvature is considered. Additionally, the stiffness of diaphragmatic plates has been introduced in the formulation in order to compare with the case where rigid diaphragms are ...

متن کامل

Three Dimensional Modelling and Optimisation of Multistage Collectors

Multistage collectors are commonly used in travelling wave tubes (TWTs), klystrons, gyrotrons and inductive output tubes (IOTs). A dc beam transfers some of its energy to the input RF wave during its travel through the interaction circuit. The purpose of a collector is to recover most of the remaining dc power from the spent beam and thereby increase both the collector and the overall efficienc...

متن کامل

FEM Implementation of the Coupled Elastoplastic/Damage Model: Failure Prediction of Fiber Reinforced Polymers (FRPs) Composites

The coupled damage/plasticity model for meso-level which is ply-level in case of Uni-Directional (UD) Fiber Reinforced Polymers (FRPs) is implemented. The mathematical formulations, particularly the plasticity part, are discussed in a comprehensive manner. The plastic potential is defined in effective stress space and the damage evolution is based on the theory of irreversible thermodynamics. T...

متن کامل

Secondary Particles Produced by Hadron Therapy

Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001