Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion

نویسندگان

  • Michael J Bey
  • Stephanie K Kline
  • Scott Tashman
  • Roger Zauel
چکیده

BACKGROUND Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS To assess the accuracy of this technique, we implanted tantalum beads into the femur and patella of three cadaveric knee specimens and then recorded dynamic biplane radiographic images while manually flexing and extending the specimen. The position of the femur and patella were measured from the biplane images using both the model-based tracking system and a validated dynamic radiostereometric analysis (RSA) technique. Model-based tracking was compared to dynamic RSA by computing measures of bias, precision, and overall dynamic accuracy of four clinically-relevant kinematic parameters (patellar shift, flexion, tilt, and rotation). RESULTS The model-based tracking technique results were in excellent agreement with the RSA technique. Overall dynamic accuracy indicated errors of less than 0.395 mm for patellar shift, 0.875 degrees for flexion, 0.863 degrees for tilt, and 0.877 degrees for rotation. CONCLUSION This model-based tracking technique is a non-invasive method for accurately measuring dynamic PF joint motion under in-vivo conditions. The technique is sufficiently accurate in measuring clinically relevant changes in PF joint motion following conservative or surgical treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring dynamic in-vivo elbow kinematics: description of technique and estimation of accuracy.

BACKGROUND The objectives of this study were to characterize the translational and rotational accuracy of a model-based tracking technique for quantifying elbow kinematics and to demonstrate its in vivo application. METHOD OF APPROACH The accuracy of a model-based tracking technique for quantifying elbow kinematics was determined in an in vitro experiment. Biplane X-ray images of a cadaveric ...

متن کامل

Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings.

BACKGROUND CONTEXT Previous research has quantified cervical spine motion with conventional measurement techniques (eg, cadaveric studies, motion capture systems, and fluoroscopy), but these techniques were not designed to accurately measure three-dimensional (3D) dynamic cervical spine motion under in vivo conditions. PURPOSE The purposes of this study were to characterize the accuracy of mo...

متن کامل

In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency.

Dynamic assessment of three-dimensional (3D) skeletal kinematics is essential for understanding normal joint function as well as the effects of injury or disease. This paper presents a novel technique for measuring in-vivo skeletal kinematics that combines data collected from high-speed biplane radiography and static computed tomography (CT). The goals of the present study were to demonstrate t...

متن کامل

Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement

OBJECTIVES Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of mov...

متن کامل

Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Orthopaedic Surgery and Research

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2008