Surgically Induced Astigmatism.

نویسندگان

  • Douglas D Koch
  • Li Wang
چکیده

To the Editor: We read with interest the article by Ofir et al.1 In 70 eyes, the authors used three devices to evaluate surgically induced astigmatism (SIA) in eyes undergoing cataract surgery with temporal 2.4-mm clear corneal incisions. Vector analysis was used appropriately to calculate the SIA in each eye.2 However, when reporting the median and mean of the SIA in the whole group, the authors calculated the median and mean of the magnitudes of the individual SIA vectors, independent of the vector angles (Figure 2, Table 2).1 Ofir et al. reported mean SIA magnitude values of 0.50 diopters (D) with the Lenstar LS900 (Haag-Streit, Koeniz, Switzerland), 0.53 D with the IOLMaster 500 (Carl Zeiss Meditec, Dublin, CA), and 0.56 D with the Atlas topographer (Carl Zeiss Meditec). Because SIA is a vector, it has both magnitude and angular direction, and both vector components must be included when calculating the median or mean SIA in a group of cases. To illustrate this, if in 2 patients the SIA is 0.5 D at 90° in both eyes, the mean SIA is 0.5 D. However, if the SIA is 0.5 D at 90° in one eye and 0.5 D at 180° in the other, the mean SIA is 0, not 0.5 D. We recommend using double angle plots with aggregate analysis of astigmatism, as first described by Holladay et al.3 Such a plot would clearly show both the mean SIA and the scatter of the individual measurements. We believe that, using aggregate analysis, Ofir et al. would find much lower values for mean SIA. We recently performed this analysis in our practice of Lenstar data of 25 eyes that also received 2.4-mm clear corneal incisions. The mean SIA was 0.13 D @ 95° (Figure 1), whereas the mean SIA magnitude was 0.39 D, close to the values reported by Ofir et al.1

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgically Induced Astigmatism Comparison between Forceps and Injector Delivery System for Foldable IOL in Phacoemulsification

Acceptance for publication May’ 2011 .................................. Purpose: To compare surgically induced astigmatism between injector and forceps delivery system for intraocular lens implantation in phacoemulsification. Methods: This Quasi experimental study was carried out in Ophthalmology Department, Shaikh Zayed Hospital, Lahore. One hundred consecutive cataract patients were operated ...

متن کامل

Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Purpose. To compare the surgically induced astigmatism from clear corneal and square posterior limbal incisions at the time of cataract surgery. Methods. Surgically induced astigmatism was calculated for a set of eyes after cataract surgery using a temporal 2.2 mm square posterior limbal incision. Results were compared to similar available data from surgeons using clear corneal incisions of sim...

متن کامل

تغییرات رفراکتیو و توپوگرافیک قرنیه پس از عمل جراحی

  Background & Aim: Refractive change after strabismus surgery is a known phenomenon which may be attributed to the extraocular muscle traction.Since previous studies were often done by conventional methods,accompanied by a short follow-up, and without considering simultaneous evaluation of both refractive and topographic changes, this study was organized to evaluate refractive and topographic ...

متن کامل

Astigmatism induced by conventional spherical ablation after PRK and LASIK in myopia with astigmatism < 1.00 D

BACKGROUND The purpose of this study was to evaluate surgically-induced astigmatism after spherical ablation in photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) for myopia with astigmatism < 1.00 D. METHODS The charts of patients undergoing spherical PRK or LASIK for the correction of myopia with minimal astigmatism of <1.00 D from 2002 to 2012 at the John A...

متن کامل

[Phacoemulsification using clear cornea incision in steepest meridian].

PURPOSE To evaluate the effect of phacoemulsification through clear cornea incision in the steepest meridian (ISM), on the magnitude of preoperative keratometric astigmatism. To map the magnitude of surgically induced astigmatism (SIA) by clear cornea incision in the positions: nasal (N), temporal (T), superior temporal (ST) and inferior temporal (IT). METHODS A prospective keratometric study...

متن کامل

Surgically induced astigmatism: distinguishing between dioptric vectors and non-vectors.

To the Editor: I read with interest the October editorial, “JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery”1 by Reinstein et al.; however, some clarification is required. I advocated common standards for reporting surgically induced astigmatism in 1997.2 In 2008, a comprehensive analysis of assessment methods and statistical analysis of surgically induced astigmatism was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2015