Clinical Comparison of Pencil Beam Convolution and Clarkson Algorithms for Dose Calculation

نویسندگان

  • Abdulhamid Chaikh
  • Jean-Yves Giraud
  • Jacques Balosso
چکیده

Purpose: The purpose of this work is to study and quantify the differences in calculated dose computed with two algorithms available in treatment planning systems: Pencil Beam Convolution and Clarkson. Material and Methods: Four different types of treatment cases were analyzed: lung, head and neck, brain and prostate. For each case, the volume definition was based on a clinical CT-scan acquisition. The patients were treated with 3-dimensional radiation therapy. For each patient, 2 treatment plans were generated using exactly the same configuration of beams. In plan 1 and plan 2, the dose was calculated using the Clarkson and Pencil Beam Convolution algorithms, respectively, without heterogeneity correction. To evaluate the treatment plans, the monitor units, isodose curves, dose volume histograms and quality index were compared. A statistical analysis was carried out using Wilcoxon signed rank test. Results: The difference observed for monitor unites was 1.2% for lung and less than 1% for head and neck, brain and prostate. Wilcoxon test showed that there was “no statically significant difference, (p > 0.05)”. The dosimetric parameters derived from dose volume histograms were higher for organs at risks using Clarkson compared to Pencil Beam Convolution algorithm inviting clinician to make “safer” prescriptions. For quality index there was no statistically significant difference between both algorithms for all quality indexes, (p > 0.05). Conclusion: The clinical evaluation of a treatment plan should be made regarding the calculation algorithm which, in turn, is linked to the experience of the clinician.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

Evaluation of Dose Calculation Algorithms Accuracy for Eclipse, PCRT3D, and Monaco Treatment Planning Systems Using IAEA TPS commissioning tests in a Heterogeneous Phantom

Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was sc...

متن کامل

Assessment of two different dose distribution algorithms (Clarkson and Superposition) in PCRT3D treatment planning system for Esophagus Cancer by using 3DCRT technique

Introduction: The functionality and quality of any treatment planning system (TPS) strongly depends on the type of Algorithm which is used by it. Obviously, the role of dose distribution algorithms in calculation of prescribed dose inside the tumor in modern radiotherapy techniques has more important than past to achieve the best clinical outcomes, especially in tumors which ar...

متن کامل

Comparison Between the Dose Distributions Calculated for Lung Cancer Patients Using Pencil Beam and Collapsed Cone Convolution Algorithms Introduction: The initial patient plans were developed by Novalis’s BrainSCAN treatment planning system

ID: 17560 Title: Comparison Between the Dose Distributions Calculated for Lung Cancer Patients Using Pencil Beam and Collapsed Cone Convolution Algorithms Comparison Between the Dose Distributions Calculated for Lung Cancer Patients Using Pencil Beam and Collapsed Cone Convolution Algorithms Introduction: The initial patient plans were developed by Novalis’s BrainSCAN treatment planning system ...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013