Enhanced spectral shaping in steady-state free precession imaging.

نویسندگان

  • Tolga Cukur
  • Neal K Bangerter
  • Dwight G Nishimura
چکیده

Balanced steady-state free precession (SSFP) is hindered by the inherent off-resonance sensitivity and unwanted bright fat signal. Multiple-acquisition SSFP combination methods, where multiple datasets with different fixed RF phase increments are acquired, have been used for shaping the SSFP spectrum to solve both problems. We present a new combination method (weighted-combination SSFP or WC-SSFP) that preserves SSFP contrast and enables banding-reduction and fat-water separation. Methods addressing the banding artifact have focused on either getting robust banding-reduction (complex-sum SSFP) or improved SNR efficiency (sum-of-squares SSFP). The proposed method achieves both robust banding-reduction and an SNR efficiency close to that of the sum-of-squares method. A drawback of fat suppression methods that create a broad stop-band around the fat resonance is the wedge shape of the stop-band leading to imperfect suppression. WC-SSFP improves the suppression of the stop-band without affecting the pass-band performance, and prevents fat signal from obscuring the tissues of interest in the presence of considerable resonant frequency variations. The method further facilitates the use of SSFP imaging by providing a control parameter to adjust the level of banding-reduction or fat suppression to application-specific needs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrally selective imaging with wideband balanced steady-state free precession MRI.

PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Time-Spatial Labeling Inversion Pulse: Safe, Simple and Effective Non-contrast MR Angiography

5. Shimada K, Isoda H, Okada T, et al. Noncontrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results. Eur J Radiol. 2009;70(1):111-117. 6. Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging ...

متن کامل

Linear combination steady-state free precession MRI.

A new, fast, spectrally selective steady-state free precession (SSFP) imaging method is presented. Combining k-space data from SSFP sequences with certain phase schedules of radiofrequency excitation pulses permits manipulation of the spectral selectivity of the image. For example, lipid and water can be resolved. The contrast of each image depends on both T1 and T2, and the relative contributi...

متن کامل

Fat-suppressed steady-state free precession imaging using phase detection.

Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetiti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 58 6  شماره 

صفحات  -

تاریخ انتشار 2007