Multicenter evaluation of an automated assay for troponin I.

نویسندگان

  • Denise Uettwiller-Geiger
  • Alan H B Wu
  • Fred S Apple
  • Anthony W Jevans
  • Per Venge
  • Marilyn D Olson
  • Claude Darte
  • David L Woodrum
  • Sean Roberts
  • Stephen Chan
چکیده

BACKGROUND Cardiac troponin I (cTnI) is a powerful tool to aid in the diagnosis of myocardial infarction and cardiac muscle damage. We describe an assay that overcomes problems of early assays that were often affected by cTnI degradation, assay interference, poor sensitivity, and imprecision. METHODS The analytical performance of the Access AccuTnI assay (Beckman Coulter) was evaluated at five institutions. Controls, zero calibrator, and diluted patient samples were used to determine precision, detection limit, functional sensitivity, and linearity. The 97.5 and 99 percentiles of a reference population were determined. Common interferents and heterophilic patient samples were tested. Equimolarity was determined by assaying samples with various ratios of free and complexed cTnI. Matched samples drawn into serum, EDTA, lithium heparin, and sodium heparin sample tubes were compared. RESULTS Total imprecision (CVs) was 4.0-8.8% between 0.40 and 31 microg/L cTnI. The detection limit was <0.01 microg/L. The 97.5 percentile upper reference limit (URL) was 0.03 microg/L (CV = 20%), and the 99 percentile URL was 0.04 microg/L (CV = 14%). Total CVs of 10% and 20% were seen at and above 0.06 and 0.03 microg/L, respectively. The assay was linear to >60 microg/L and not affected by common assay interferents. An equimolar response was observed with free, complexed, phosphorylated, and dephosphorylated forms of cTnI. Results were 4% lower in serum and 14% lower in EDTA plasma than in lithium heparin plasma (P <0.01), independent of cTnI concentration. CONCLUSION AccuTnI is a sensitive and precise assay for the measurement of cTnI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum troponin I as an indicator of myocarditis in lambs affected with foot and mouth disease

Foot and mouth disease (FMD) is a highly contagious viral disease of cloven-hooved livestock and wildlife results to relatively high mortality in young animals. Despite the numerous reports of FMD-related death in neonates, there is little data available on various aspects of FMD in lambs. This report describes myocarditis associated with FMD in five, one week to three months old lambs. The lam...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

Multicenter evaluation of analytical performance of the Liaison troponin I assay.

OBJECTIVES This study evaluated the analytical characteristics of the Liaison immunoassay for cardiac troponin I (cTnI). DESIGN AND METHODS The protocol consisted of eight sections: evaluation of antibody specificity, linearity, detection limit and imprecision, method comparison, evaluation of endogenous interferents, anticoagulant interference, sample stability, and reference values. RESUL...

متن کامل

Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn&rsquo;t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2002