Cell culture monitoring via an auto-sampler and an integrated multi-functional off-line analyzer.

نویسندگان

  • Gayle E Derfus
  • Daniel Abramzon
  • Meg Tung
  • David Chang
  • Robert Kiss
  • Ashraf Amanullah
چکیده

Mammalian cell-based bioprocesses are used extensively for production of therapeutic proteins. Off-line monitoring of such cultivations via manual sampling is often labor-intensive and can introduce operator-dependent error into the process. An integrated multi-functional off-line analyzer, the BioProfile FLEX (NOVA Biomedical, Waltham MA) has been developed, which combines the functionality of three off-line analyzers (a cell counter, an osmometer, and a gas/electrolyte & nutrient/metabolite bio-profile analyzer) into one device. In addition, a novel automated sampling system has also been developed that allows the BioProfile FLEX to automatically analyze the culture conditions in as many as ten bioreactors. This is the first report on the development and function of this integrated analyzer and an auto-sampler prototype for monitoring of mammalian cell cultures. Evaluation of the BioProfile FLEX was conducted in two separate laboratories and involved two BioProfile FLEX analyzers and two sets of reference analyzers (Nova BioProfile 400, Beckman-Coulter Vi-Cell AS, and Advanced Instruments Osmometer 3900), 13 CHO cell lines and over 20 operators. In general, BioProfile FLEX measurements were equivalent to those obtained using reference analyzers, and the auto-sampler did not alter the samples it provided to the BioProfile FLEX. These results suggest that the system has the potential to dramatically reduce the manual labor involved in monitoring mammalian cell bioprocesses without altering the quality of the data obtained, and integration with a bioreactor control system will allow feedback control of parameters previously available only for off-line monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer

Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...

متن کامل

AN INTEGRATED FIS-QFD MODEL FOR EVALUATION OF INTERNET SERVICE PROVIDER

<span style="color: #000000; font-family: Tahoma, sans-serif; font-size: 13px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: auto; text-align: -webkit-left; text-indent: 0px; text-transform: none; white-space: normal; widows: auto; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none; ba...

متن کامل

AN INTEGRATED FIS-QFD MODEL FOR EVALUATION OF INTERNET SERVICE PROVIDER

<span style="color: #000000; font-family: Tahoma, sans-serif; font-size: 13px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: auto; text-align: -webkit-left; text-indent: 0px; text-transform: none; white-space: normal; widows: auto; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none; ba...

متن کامل

Integrating Disparate Analytical Instrumentation into an Automated Process Control System Used in Cell Culture Process Development

This case study of a cell culture process development lab shows how various common analytical instruments were quickly and effectively integrated into a comprehensive process control and data management system. Streaming time-stamped results from these instruments directly into the process control system enabled automated real-time feedback and advanced characterizations of cell viability, inst...

متن کامل

An Auto-validating Rejection Sampler

In Bayesian statistical inference and computationally intensive frequentist inference, one is interested in obtaining samples from a high dimensional, and possibly multi-modal target density. The challenge is to obtain samples from this target without any knowledge of the normalizing constant. Several approaches to this problem rely on Monte Carlo methods. One of the simplest such methods is th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biotechnology progress

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2010