A generalized procedure for calibrated MRI incorporating hyperoxia and hypercapnia.
نویسندگان
چکیده
Calibrated MRI techniques use the changes in cerebral blood flow (CBF) and blood oxygenation level-dependent (BOLD) signal evoked by a respiratory manipulation to extrapolate the total BOLD signal attributable to deoxyhemoglobin at rest (M). This parameter can then be used to estimate changes in the cerebral metabolic rate of oxygen consumption (CMRO(2)) based on task-induced BOLD and CBF signals. Different approaches have been described previously, including addition of inspired CO(2) (hypercapnia) or supplemental O(2) (hyperoxia). We present here a generalized BOLD signal model that reduces under appropriate conditions to previous models derived for hypercapnia or hyperoxia alone, and is suitable for use during hybrid breathing manipulations including simultaneous hypercapnia and hyperoxia. This new approach yields robust and accurate M maps, in turn allowing more reliable estimation of CMRO(2) changes evoked during a visual task. The generalized model is valid for arbitrary flow changes during hyperoxia, thus benefiting from the larger total oxygenation changes produced by increased blood O(2) content from hyperoxia combined with increases in flow from hypercapnia. This in turn reduces the degree of extrapolation required to estimate M. The new procedure yielded M estimates that were generally higher (7.6 ± 2.6) than those obtained through hypercapnia (5.6 ± 1.8) or hyperoxia alone (4.5 ± 1.5) in visual areas. These M values and their spatial distribution represent a more accurate and robust depiction of the underlying distribution of tissue deoxyhemoglobin at rest, resulting in more accurate estimates of evoked CMRO(2) changes.
منابع مشابه
Magnetic resonance imaging of resting OEF and CMRO2 using a generalized calibration model for hypercapnia and hyperoxia
We present a method allowing determination of resting cerebral oxygen metabolism (CMRO₂) from MRI and end-tidal O₂ measurements acquired during a pair of respiratory manipulations producing different combinations of hypercapnia and hyperoxia. The approach is based on a recently introduced generalization of calibrated MRI signal models that is valid for arbitrary combinations of blood flow and o...
متن کاملThe impact of inspired oxygen levels on calibrated fMRI measurements of M, OEF and resting CMRO2 using combined hypercapnia and hyperoxia
Recent calibrated fMRI techniques using combined hypercapnia and hyperoxia allow the mapping of resting cerebral metabolic rate of oxygen (CMRO2) in absolute units, oxygen extraction fraction (OEF) and calibration parameter M (maximum BOLD). The adoption of such technique necessitates knowledge about the precision and accuracy of the model-derived parameters. One of the factors that may impact ...
متن کاملAbsolute quantification of resting oxygen metabolism and metabolic reactivity during functional activation using QUO2 MRI
We have recently described an extension of calibrated MRI, which we term QUO2 (for QUantitative O(2) imaging), providing absolute quantification of resting oxidative metabolism (CMRO(2)) and oxygen extraction fraction (OEF(0)). By combining BOLD, arterial spin labeling (ASL) and end-tidal O(2) measurements in response to hypercapnia, hyperoxia and combined hyperoxia/hypercapnia manipulations, a...
متن کاملQuantitative functional neuroimaging of cerebral physiology in healthy aging
Functional MRI (fMRI) studies using the BOLD signal are done under the general assumption that the BOLD signal can be used as a direct index of neuronal activation. Studies of cognitive aging often compare BOLD signal amplitude and extent directly between younger and older groups, with the additional assumption that the relationship between neuronal activity and the hemodynamic response is unch...
متن کاملHemodynamic response magnetic resonance imaging: application for renal hemodynamic characterization.
BACKGROUND The clinical use of iodinated radiocontrast agents or gadolinium for renal perfusion imaging is limited in the presence of renal dysfunction. We have previously demonstrated the feasibility of hemodynamic response imaging (HRI), a functional magnetic resonance imaging (MRI) method combined with hypercapnia and hypercapnic-hyperoxia, for monitoring changes in liver perfusion and hemod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Human brain mapping
دوره 34 5 شماره
صفحات -
تاریخ انتشار 2013