Compensation of Unidirectional Geometric Distortion in EPI Using Spline Warping
نویسندگان
چکیده
Due to magnetic field inhomogeneities, EPI images are geometrically distorted, predominantly along the phase-encoding direction. Currently, the distortion is either ignored or compensated manually using a warping function defined through a set of landmarks. We propose an automatic method to unwarp the geometric distortion of EPI images by registering them with corresponding undistorted anatomical MRI images. We show that cubic splines are optimal interpolating functions for both landmark interpolation and approximation. We will consequently use the same warping space in our algorithm which replaces landmarks by an image difference criterion. B-splines are used as generating functions, which leads to a fast and accurate computation. Multiresolution gives robustness and additional speedup. The algorithm performance was evaluated using both real and synthetic data and was found superior to the manual method.
منابع مشابه
Multiresolution spline warping for EPI registration
Registration of images subject to non-linear warping has numerous practical applications. We present an algorithm based on double multiresolution structure of warp and image spaces. Tuning a so-called scale parameter controls the coarseness of the grid by which the deformation is described and also the amount of implicit regularization. The application of our algorithm deals with undoing unidir...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملConcurrent Geometric Distortion Correction in Mapping Slice-to-volume (MSV) Motion Correction of fMRI Time Series
D. Yeo, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data, from which brain activation maps are computed, is se...
متن کاملComparison of EPI Distortion Correction Methods in Diffusion Tensor MRI
Introduction Diffusion weighted images (DWIs) used for Diffusion Tensor (DT) calculation are commonly acquired with Echo-planar imaging (EPI). Unfortunately, EPI is very sensitive to magnetic field (B0 ) inhomogeneities, which result in local geometric distortions in regions close to air-tissue interfaces. These distortions degrade the anatomical accuracy of DT-MRI maps and potentially increase...
متن کاملPassive-Active Geometric Calibration for View-Dependent Projections onto Arbitrary Surfaces
In this paper we present a hybrid technique for correcting distortions that appear when projecting images onto geometrically complex, colored and textured surfaces. It analyzes the optical flow that results from perspective distortions during motions of the observer and tries to use this information for computing the correct image warping. If this fails due to an unreliable optical flow, an acc...
متن کامل