Accuracy of noncycloplegic retinoscopy, retinomax autorefractor, and SureSight vision screener for detecting significant refractive errors.

نویسندگان

  • Marjean Taylor Kulp
  • Gui-Shuang Ying
  • Jiayan Huang
  • Maureen Maguire
  • Graham Quinn
  • Elise B Ciner
  • Lynn A Cyert
  • Deborah A Orel-Bixler
  • Bruce D Moore
چکیده

PURPOSE To evaluate, by receiver operating characteristic (ROC) analysis, the ability of noncycloplegic retinoscopy (NCR), Retinomax Autorefractor (Retinomax), and SureSight Vision Screener (SureSight) to detect significant refractive errors (RE) among preschoolers. METHODS Refraction results of eye care professionals using NCR, Retinomax, and SureSight (n = 2588) and of nurse and lay screeners using Retinomax and SureSight (n = 1452) were compared with masked cycloplegic retinoscopy results. Significant RE was defined as hyperopia greater than +3.25 diopters (D), myopia greater than 2.00 D, astigmatism greater than 1.50 D, and anisometropia greater than 1.00 D interocular difference in hyperopia, greater than 3.00 D interocular difference in myopia, or greater than 1.50 D interocular difference in astigmatism. The ability of each screening test to identify presence, type, and/or severity of significant RE was summarized by the area under the ROC curve (AUC) and calculated from weighted logistic regression models. RESULTS For detection of each type of significant RE, AUC of each test was high; AUC was better for detecting the most severe levels of RE than for all REs considered important to detect (AUC 0.97-1.00 vs. 0.92-0.93). The area under the curve of each screening test was high for myopia (AUC 0.97-0.99). Noncycloplegic retinoscopy and Retinomax performed better than SureSight for hyperopia (AUC 0.92-0.99 and 0.90-0.98 vs. 0.85-0.94, P ≤ 0.02), Retinomax performed better than NCR for astigmatism greater than 1.50 D (AUC 0.95 vs. 0.90, P = 0.01), and SureSight performed better than Retinomax for anisometropia (AUC 0.85-1.00 vs. 0.76-0.96, P ≤ 0.07). Performance was similar for nurse and lay screeners in detecting any significant RE (AUC 0.92-1.00 vs. 0.92-0.99). CONCLUSIONS Each test had a very high discriminatory power for detecting children with any significant RE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ROC analysis of the accuracy of Noncycloplegic retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for preschool vision screening.

PURPOSE To evaluate, by receiver operating characteristic (ROC) analysis, the accuracy of three instruments of refractive error in detecting eye conditions among 3- to 5-year-old Head Start preschoolers and to evaluate differences in accuracy between instruments and screeners and by age of the child. METHODS Children participating in the Vision In Preschoolers (VIP) Study (n = 4040), had scre...

متن کامل

Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology Accuracy of Noncycloplegic Retinoscopy, Retinomax Autorefractor, and SureSight Vision Screener for Detecting Significant Refractive Errors

The Ohio State University College of Optometry, Columbus, Ohio University of Pennsylvania, Philadelphia, Pennsylvania Children’s Hospital of Pennsylvania, Philadelphia, Pennsylvania Pennsylvania College of Optometry at Salus University, Elkins Park, Pennsylvania Northeastern State University, Oklahoma College of Optometry, Tahlequah, Oklahoma University of California Berkeley School of Optometr...

متن کامل

The Vision in Preschoolers Study Group

Purpose. To compare the sensitivity of 11 preschool vision screening tests administered by licensed eye care professionals for the detection of the 4 Vision in Preschoolers (VIP)-targeted vision disorders when specificity is 94%. Methods. This study consisted of a sample (n 2588) of 3to 5-year-old children enrolled in Head Start programs, 57% of whom had failed an initial Head Start vision scre...

متن کامل

Does assessing eye alignment along with refractive error or visual acuity increase sensitivity for detection of strabismus in preschool vision screening?

PURPOSE Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. ...

متن کامل

Findings from the Vision in Preschoolers (VIP) Study.

The Vision in Preschoolers (VIP) Study Group conducted a multicenter, multidisciplinary, two-phase study to evaluate the performance of vision screening tests for identifying pre-school children with amblyopia, strabismus, significant refractive error, or unexplained reduced visual acuity (VA). The results of the VIP Study provide evidence-based guidelines for preschool vision screening. The be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 2014