Integration of FDG-PET/CT into external beam radiation therapy planning: technical aspects and recommendations on methodological approaches.

نویسندگان

  • D Thorwarth
  • T Beyer
  • R Boellaard
  • D de Ruysscher
  • A Grgic
  • J A Lee
  • U Pietrzyk
  • B Sattler
  • A Schaefer
  • W van Elmpt
  • W Vogel
  • W J G Oyen
  • U Nestle
چکیده

UNLABELLED This work addresses the clinical adoption of FDG-PET/CT for image-guided radiation therapy planning (RTP). As such, important technical and methodological aspects of PET/CT-based RTP are reviewed and practical recommendations are given for routine patient management and clinical studies. First, recent developments in PET/CT hardware that are relevant to RTP are reviewed in the context of quality control and system calibration procedures that are mandatory for a reproducible adoption of PET/CT in RTP. Second, recommendations are provided on image acquisition and reconstruction to support the standardization of imaging protocols. A major prerequisite for routine RTP is a complete and secure data transfer to the actual planning system. Third, state-of-the-art tools for image fusion and co-registration are discussed briefly in the context of PET/CT imaging pre- and post-RTP. This includes a brief review of state-of-the-art image contouring algorithms relevant to PET/CT-guided RTP. Finally, practical aspects of clinical workflow and patient management, such as patient setup and requirements for staff training are emphasized. PET/CT-guided RTP mandates attention to logistical aspects, patient set-up and acquisition parameters as well as an in-depth appreciation of quality control and protocol standardization. CONCLUSION Upon fulfilling the requirements to perform PET/CT for RTP, a new dimension of molecular imaging can be added to traditional morphological imaging. As a consequence, PET/CT imaging will support improved RTP and better patient care. This document serves as a guidance on practical and clinically validated instructions that are deemed useful to the staff involved in PET/CT-guided RTP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integration der FDG-PET/CT-Bildgebung in die Planung der externen Strahlentherapie â Technische Aspekte und Empfehlungen zur methodischen Annäherung

This work addresses the clinical adoption of FDG-PET/CT for image-guided radiation therapy planning (RTP). As such, important technical and methodological aspects of PET/CTbased RTP are reviewed and practical recommendations are given for routine patient management and clinical studies. First, recent developments in PET/CT hardware that are relevant to RTP are reviewed in the context of quality...

متن کامل

A Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.

 Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...

متن کامل

Primary Thyroid Lymphoma: External Beam Radiation Therapy Induced Thyroiditis Mimics Residual Disease on Serial 18F-FDG PET/CT Imaging

A 67-year-old female patient with no prior history of benign thyroid disease was diagnosed with primary thyroid lymphoma and was staged with 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT). She was treated with chemotherapy and external beam radiation therapy, and a follow-up PET/CT showed significant reduction in the size of the thyroid lymphoma...

متن کامل

Clinical Impact of 18F-FDG PET/CT on the Management of Gynecologic Cancers: One Center Experience

Objective(s): We aim to investigate the clinical impact of 18F-FDG PET/CT in managing patients with gynecological malignancies and pelvic or extrapelvic lymph nodes that are of equivocal significance on conventional imaging.Methods: We retrospectively evaluated 18F-FDG PET/CT scans of patients with gynecologic tumors who were referred to King Hussein Cancer Center from January 2010 to August 20...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuklearmedizin. Nuclear medicine

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2012