Model Reduction and Sensor Placement Methods for Finite Element Model Correlation
نویسنده
چکیده
The issue of model reduction is one that must often be overcome in order to perform the necessary checks as part of the spacecraft Finite Element Model (FEM) validation process. This work compares different reduction methods; specifically the popular and long-standing Guyan method, and the potentially more accurate System Equivalent Reduction Expansion Process (SEREP). The influence of sensor set location on the quality of the reduced model has also been considered, and the commonly applied methods to maximize kinetic energy and effective independence have been applied. These investigations have taken the form of studies involving two large, unique, scientific spacecraft. The computational results are compared with experimental results that are also detailed in the paper. The findings highlight the potential issues with the accuracy of a Guyan reduced model in replicating the full system dynamics, even with a reasonably large sensor set. It is shown that this can be improved slightly in some circumstances through implementation of sensor set placement optimization techniques. The SEREP method is shown to have the benefit of being more accurate at replicating the full system behavior than the more traditional Guyan method, while also producing higher diagonal values in cross-orthogonality comparisons between FEM and test.
منابع مشابه
Implementing the most efficient sensor placement methods on the ship structural model
The damage and failure in engineering structures, especially offshore structures, and hull of ship structures, causes economic losses, human disasters, and environmental problems. Therefore, diagnosing and predicting the occurrence of failure in these structures is vital. In this situation, engineers have introduced the use of structural health monitoring operations as a suitable way to prevent...
متن کاملNew Design of Mems piezoresistive pressure sensor
The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...
متن کاملFrequency Domain Model Reduction Based on Principal Component Analysis
A new frequency response based model reduction technique is presented for use in the mid-frequency range. The reduction was designed to avoid the use of modal based correlation metrics, which are known to fail in systems with high modal density. A transformation matrix based on a set of complex shapes extracted from the frequency response is used to reduce the impedance matrix to the sensor loc...
متن کاملDesign and evaluation of two distributed methods for sensors placement in Wireless Sensor Networks
Adequate coverage is one of the main problems for distributed wireless sensor networks and The effectiveness of that highly depends on the sensor deployment scheme. Given a finite number of sensors, optimizing the sensor deployment will provide sufficient sensor coverage and save power of sensors for movement to target location to adequate coverage. In this paper, we apply fuzzy logic system to...
متن کاملDesign and evaluation of two distributed methods for sensors placement in Wireless Sensor Networks
Adequate coverage is one of the main problems for distributed wireless sensor networks and The effectiveness of that highly depends on the sensor deployment scheme. Given a finite number of sensors, optimizing the sensor deployment will provide sufficient sensor coverage and save power of sensors for movement to target location to adequate coverage. In this paper, we apply fuzzy logic system to...
متن کامل